Charging Procedure
1. Check the specific gravity and adjust the
electrolyte level.
2. Disconnect the battery cables.
3. Connect the red clip of the charger
(Figure 12-7, (1)) to the positive (+) battery
terminal and connect the black clip to the
negative (-) terminal.
Figure 12-7
Figure 12-7
1 – Battery Charger
2 – Battery
4. Set the current to 1/10 to 1/5 of the capacity
indicated on the outside of the battery
(Figure 12-7, (2)).
5. Periodically measure the specific gravity during
charging to make sure the specific gravity
remains at a high fixed value. Also check
whether gas is being generated.
12-6
(2)
(1)
0006266
© 2007 Yanmar Marine International
Battery Components and Functions
Charging Precautions
1. Remove the battery caps to vent the gas during
charging.
2. The electrolyte temperature should not exceed
45°C (113°F) during charging.
Figure 12-8
Electrolyte Temperature
Figure 12-8
3. Since an alternator is used on this engine when
charging with a charger, always disconnect the
battery cables to prevent destruction of the
diodes in the alternator.
NOTICE: Disconnect the negative (-) cable first.