Rear Vent - Heat & Glo SL-750TRS-IPI-D Owner's Manual

Hide thumbs Also See for SL-750TRS-IPI-D:
Table of Contents

Advertisement

To attach the rst section of vent pipe, make
Figure 7.7
sure to use the berglass gasket in the manual bag to seal
between the rst vent component and the outer replace
wrap. Use 2 self tapping screws to secure the gasket to
the outer wrap.
Secure the rst section of venting to the replace by screw-
ing through the two tabs bent up out of the vent hole in the
heat shield. Note: Once the vent cap has been removed,
it cannot be reattached.
B.

Rear Vent

Fold the tabs toward the center of the re plug
Figure 7.6
(90°) and remove the insulation gasket.
Cut the metal retaining band and fold the
Figure 7.7
sides out.
Heat & Glo • SL-750TRS-IPI-D, SL-550TRS-IPI-D, SL350TRS-C • InD • 2065-985 Rev. o • 3/07
Fold the center parts of the retaining band out
Figure 7.8
and use to remove the vent cap.
Discard the vent cap, remove and discard the
Figure 7.9
insulation basket. Note: Once the vent cap has been re-
moved it CANNOT be reattached.
Attach the rst vent section (it will snap into
Figure 7.10
place). Slide the insulation gasket onto the vent section,
up against the appliance and over the tabs.
27

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sl-350trs-cSl-550trs-ipi-d

Table of Contents