Constructing The Appliance Chase; Clearances - Heat & Glo SL-750TRS-IPI-D Owner's Manual

Hide thumbs Also See for SL-750TRS-IPI-D:
Table of Contents

Advertisement

B.

Constructing the Appliance Chase

A chase is a vertical boxlike structure built to enclose the
gas appliance and/or its vent system. Vertical vents that run
on the outside of a building may be, but are not required to
be, installed inside a chase.
Construction of the chase may vary with the type of building.
These instructions are not substitutes for the requirements
of local building codes. Local building codes MUST be
checked.
Chases should be constructed in the manner of all outside
walls of the home to prevent cold air drafting problems.
The chase should not break the outside building envelope
in any manner.
Walls, ceiling, base plate and cantilever oor of the chase
should be insulated. Vapor and air in ltration barriers should
be installed in the chase as per regional codes for the rest of
the home. Additionally, in regions where cold air in ltration
may be an issue, the inside surfaces may be sheetrocked
and taped for maximum air tightness.
To further prevent drafts, the wall shield and ceiling restops
should be caulked with high temperature caulk to seal gaps.
Gas line holes and other openings should be caulked with
B
D
Models
Inches
SL-750TRS-IPI-D
Millimeters
Inches
SL-550TRS-IPI-D
Millimeters
Inches
SL-350TRS-C
Millimeters
Figure 3.2
Clearances to Combustibles
Heat & Glo • SL-750TRS-IPI-D, SL-550TRS-IPI-D, SL-350TRS-C • InD • 2065-985 Rev. o • 3/07
8
A
C
A
B
DVP PIPE
SL PIPE
DVP PIPE
Rough
Opening
Rough
Rough
(Height)
Opening
Opening
Opening
(Width)
(Width)
(Depth)
10
8-5/8
38-1/4
27-1/2
254
219
971
10
8-5/8
33
27-1/2
254
219
838
10
8-5/8
31
27-1/2
254
219
787
high temp caulk or stuffed with unfaced insulation. If the
appliance is being installed on a cement slab, a layer of
plywood may be placed underneath to prevent conducting
cold up into the room.
C.

Clearances

F
J
C
D
E
SL PIPE
Clearance
Rough
Opening
to Ceiling
Rough
Rough
(Width)
Opening
(Depth)
16-1/4
42
31
699
413
1067
787
16-1/4
37
31
699
413
940
787
16-1/4
34
31
699
413
864
787
WARNING
Fire Risk.
Odor Risk.
Install appliance on hard metal or wood
surfaces extending full width and depth of
appliance.
Do NOT install appliance directly on
carpeting, vinyl, tile or any combustible
material other than wood.
WARNING
Fire Risk.
Construct chase to all clearance
speci cations in manual.
Locate and install appliance to all
clearance speci cations in manual
FROM TOP
OF HOOD
TO CEILING
G
I
F
G
H
Non-Combustible
Combustible
Behind
Floor
Flooring
Appliance
0
0
1/2
0
0
13
0
0
1/2
0
0
13
0
0
1/2
0
0
13
E
H
I
J
Sides of
Front of
Appliance
Appliance
1/2
36
13
915
1/2
36
13
915
1/2
36
13
915

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sl-350trs-cSl-550trs-ipi-d