Reliance electric 1203-USB Instruction Manual page 43

Usb converter
Table of Contents

Advertisement

Converter Parameters
Appendix B provides information about the 1203-USB converter parameters.
Parameter List for DPI Drives
Parameter List for MDI Drives
Parameter List for DPI Drives
No.
Name and Description
01
DPI Port
Displays the port on the host drive to
which the converter is connected.
02
Reset Module
No action if set to "Ready." Resets the
converter if set to "Reset Module."
Restores the converter to its
factory-default settings if set to "Set
Defaults." This parameter is a command. It
will be reset to "0 = Ready" after the
command has been performed.
!
Converter Parameters
Topic
ATTENTION: Risk of injury or equipment damage exists. If
the converter is transmitting I/O that controls the drive
(indicated by a solid green diamond LED), the drive may fault
when you remove or reset the converter. Determine how your
drive will respond before removing or resetting a connected
converter.
A
PPENDIX
Page
B-1
B-3
Details
Default: 0
Minimum:0
Maximum:7
Type:Read Only
Default:
0 = Ready
Values:
0 = Ready
1 = Reset Module
2 = Set Defaults
Type:
Read/Write
Reset Required:No