6-1 Daily Care

Cleaning

WARNING
WARNING
WARNING
WARNING
CAUTION
CAUTION
 Carefully clean away cutting waste. Operating the machine with a large amount of cutting waste present may cause
malfunction.
 Never apply lubrication anywhere except at specified locations.
 Never apply silicone substances (oil, grease, spray, etc.) to the machine. Doing so may cause poor switch contact.

Cleaning Inside the Front Cover

Open the front cover and clean away any buildup of cutting waste inside.
Never touch these rails.
96

Chapter 6 Maintenance

Never use a pneumatic blower.
This machine is not compatible with a pneumatic blower. Cutting waste may get
inside the machine and cause fire or electrical shock.
Never use a solvent such as gasoline, alcohol, or thinner to perform cleaning.
Doing so may cause fire.
Disconnect the power cord before performing cleaning or maintenance.
Attempting such operations while the machine is connected to a power source may
result in injury or electrical shock.
When using a vacuum cleaner to take up cutting waste, exercise caution to prevent
fire or dust explosion.
Taking up fine cuttings using an ordinary vacuum cleaner may cause danger of
fire or explosion. Check with the manufacturer of the vacuum cleaner. When the
safety of use cannot be determined, clean using a brush or the like, without using
the vacuum cleaner
Caution: high temperatures.
The cutting tool and spindle motor become hot. Exercise caution to avoid fire or
burns.
When performing maintenance, be sure to keep the tool detached.
Contact with the blade may cause injury.