Wind Transducer Setup - Raymarine ST70+ Installation Manual

Hide thumbs Also See for ST70+:
Table of Contents

Advertisement

46
OK
7. Press
menu.
8. If you have:
• A Wind transducer, carry out the Wind
transducer setup procedure below.
• A Speed transducer, carry out the Speed
calibration on page 47.

Wind transducer setup

The wind transducer setup procedures are used to:
Linearize the vane.
Align the vane.
Calibrate the wind speed.
Linearization
To linearize the wind vane:.
1. With the Transducers found menu displayed
(see Preliminary procedure on page 45), scroll
to the Wind option.
OK
2. Press
menu.
3. Scroll to the Calibrate Vane option.
OK
4. Press
screen.
5. Keeping the boat speed below 2 knots and
observing the screen, turn the boat in circles,
then press
6. Observe the Calibrate Vane run screen and
continue turning the boat:
• If the boat speed is too high during calibra-
tion, a Slow down message is displayed. If
this happens, reduce your speed.
• Calibration completes automatically.
7. When calibration is complete, the Wind transducer setup menu is displayed.
to display the Transducers found
to select the Wind transducer setup
to select the Calibrate Vane start
OK
to start the calibration.
ST70+ User Reference Manual
Transducers Found
Depth
Raymarine
i
Serial no.135260
Press OK to select
Transducers found
Wind
Raymarine
i
Serial no.176342
Press OK to select
Wind
Calibrate Vane
Raymarine
i
Serial no.176342
Press OK to select
Calibrate Vane
Move in a slow circle, below 2kts.
i
Watch for 'too fast' on display.
Press OK to continue