7 Graphical User Interface (GUI)

7.2.1 Exposure

This tab contains exposure settings.
Figure 7.11: MV-D1024E-160 exposure panel
Exposure
Exposure time [ms :] Configure the exposure time in milliseconds.
Constant Frame Rate: When the Constant Frame Rate (CFR) is switched on, the frame rate
(number of frames per second) can be varied from almost 0 up to the maximum frame
rate. Thus, fewer images can be acquired than would otherwise be possible. When
Constant Frame Rate is switched off, the camera delivers images as fast as possible,
depending on the exposure time and the read-out time.
Frame time [ms :] Configure the frame time in milliseconds. Only available if Constant Frame
Rate is enabled. The minimum frame time depends on the exposure time and readout
time.
Information
The Information properties provide information about the acquired images.
Image Counter: The image counter is a 24 bit real-time counter and is incremented by 1 for
every new image.
Missed Trigger Counter: This is a counter for trigger pulses that were blocked because the
trigger pulse was received during image exposure or readout. In free-running mode it
counts all pulses received from interface trigger or from I/O trigger interface.
Status Line: The status line replaces the last line of an image with image information.
To update the value of the information properties, click on the Update-Button; to reset the
properties, click on the Reset-Button.