GPS Tracker GSM/GPRS/ User Manual

GPS Tracker GSM/GPRS/ User Manual

Gsm/gprs/gps tracker

Advertisement

1
GSM/GPRS/GPS Tracker
User Manual
Preface
Thank you for purchasing the tracker. This manual shows how to operate the device smoothly
and correctly. Make sure to read this manual carefully before using this product. Please note
that specification and information are subject to changes without prior notice in this manual.
Any change will be integrated in the latest release. The manufacturer assumes no
responsibility for any errors or omissions in this document.

Advertisement

Table of Contents
loading

Summary of Contents for GPS Tracker GSM/GPRS/GPS Tracker

  • Page 1 GSM/GPRS/GPS Tracker User Manual Preface Thank you for purchasing the tracker. This manual shows how to operate the device smoothly and correctly. Make sure to read this manual carefully before using this product. Please note that specification and information are subject to changes without prior notice in this manual.
  • Page 2: Table Of Contents

    Contents 1. Summary ..................................4 2. Applications ................................4 3. Hardware Description ..............................4 4. Accessories ................................. 5 5. Specifications ................................5 6. Usage ..................................6 6.1 Terminal Installation ............................6 6.2SIM CARD Installations ............................7 6.3 Turn on the Tracker Device..........................7 6.4 GSM/GPS LED Indicator ...........................
  • Page 3 6.25.1 ACC alarm ..............................22 6.25.2 Shock Sensor alarm ..........................22 6.26 Alarm without GSM network service......................23 6.27 Sleep Mode..............................23 6.27.1 Sleep by time ............................23 6.27.2 Sleep by shock sensor ..........................23 6.27.3 Deep Sleep by Shock Sensor........................23 6.27.4 No sleep mode ............................
  • Page 4: Summary

    1. Summary This tracker is based on the GSM / GPRS network and GPS satellite positioning system, which sets multiple functions of security, positioning, monitoring surveillance, emergency alarms and tracking in its entirety. It can track and monitor remote target by SMS or internet. 1.2 Features 1.2.1 IP Rating: IP66 1.2.2Internal GPS&GSM antenna, compact, elegant appearance...
  • Page 5: Accessories

    GPS/POWER/GSM Indicator 4. Accessories Type D: Add remote controller to ARM & DISARM on the basis of type C Applicable photo Name Specifications model Harness 8PIN Standard Relay 12V/40A or 24V/40A Standard Small alarm 12V/24V Optional siren Remote Optional for Controller type D 5.
  • Page 6: Usage

    8.9×5.0×1.6cm Weight Network GSM/GPRS Band 850/900/1800/1900Mhz -159dBm sensitivity accurancy Cold status 45s GPS start time Warm status 35s Hot status 1s Car power 12 V -24V supply Back up Chargeable 3.7V 500mAh Li-ion battery battery Storage Temp -40° C to +85° C Operation -20°...
  • Page 7: Wiring Diagram

    Wiring diagram 6.2SIM CARD Installations 6.2.1 Use the screwdriver accompanied with the device to open sealed buckle and insert the SIM card.If need data logging function, please insert microSD and put sealed buckle back 6.2.2Please make sure the SIM card is for GSM network and able to execute the function of incoming calls display, no calls can be diverted and the PIN code is locked.
  • Page 8: Change Password

    6.6 Change Password 6.6.1 Send SMS “password+old password+space+new password” to the unit to change the password. For example: send SMS “password123456 888888” to the unit. If succeeded, “password ok” will reply to your cell phone from the device tracker. 6.6.2 Be sure to keep the new password in mind, you have to upload the software to restore the original setting in case of losing the new password.
  • Page 9: Single Locating

    number” to delete the authorized number. 6.7.4 For roaming purpose, you have to add your country code ahead of the cell phone number, for example, please send:“admin123456 +8613322221111” to tracker to set 13322221111 as an authorized number. 6.8 Single Locating 6.8.1 Any number calls the tracker device;...
  • Page 10: Auto Track Continuously

    6.9 Auto track continuously 6.9.1 Track with limited times upon time interval: Send SMS command “fix030s005n +password” to the tracker device, it will report the latitude & longitude at intervals of 30 seconds for 5 times. (s:second, m:minute, h:hour). This command set must be in 3 digits and the maximum value is 255.
  • Page 11: Automatic Update Positions Of Vehicle Turns

    6.10 Automatic update positions of vehicle turns 6.10.1 The tracker will update the positions automatically to web server once the vehicle changing driving direction over pre set angle value to form a smooth trajectory consistent with the actual road, this function is only effective in GPRS mode.
  • Page 12: Location Based Service (Lbs)

    6.12.2 After configure the APN, send "address+password" to device, it will reply SMS including real street/address name. For example: No.113, Guankou 2nd Rd, Nantou, Nanshan district, Shenzhen, Guangdong, china. 6.13 Location based service (LBS) When the tracker device doesn’t receive valid GPS signals, tracker will positioning by location based service(LBS), the messages includes the GPS coordinates of the last position in SMS mode, but the LAC in message is the current new position, the location can be seen by input the LAC code in the...
  • Page 13: Data Logging

    6.14.2 The default mode is “track” (Track mode). 6.14.3 Send SMS “monitor+password” to the unit, and it will reply“monitor ok!” and switch to “monitor” mode. 6.14.4 Send SMS “tracker+password” to the unit, it will reply “tracker ok!” and restore to “track” mode. 6.15.Data logging 6.15.1 When the tracker device loses GSM signals or fall offline from GPRS, tracker will store the tracking position and alerts automatically upon the pre-set condition, when GSM...
  • Page 14: Data Load

    6.16. Data Load Current date Load: Send SMS: “load+ password” to tracker device, it will 6.16.1 reply: “load ok” if the device is working well under GPRS mode; if not, it will reply “load fail! Please check gprs” that means device does not work under GPRS mode.
  • Page 15: Alarm Function

    number+space+code" to tracker, it will forward the code to carrier’s phone number and return the balance message received from carrier’s phone number. 6.19. Alarm Function 6.19.1 Low battery alarm Send SMS “lowbattery+password+space+on”, it will send SMS “low 6.19.1.1. battery+latitude/longitude” to authorized numbers 2 times in total in 15 minutes when voltage of battery is going to be about 3.55V.
  • Page 16: Sos

    6.19.4 SOS Long Press the SOS button for 3 seconds ( For model D, press button on remote controller for 3 seconds), the tracker device will send SMS “help me!+lat./long.” to all the authorized numbers at interval of 3 minutes. It will stop sending such alert SMS when any authorized number reply SMS “help me”...
  • Page 17: Multi-Area Management

    6.19.6 Multi-area management 6.19.6.1 Set Area Send SMS command "area+password+space+latitude,longitude+space+areaname,distanceM" to tracker(distance unit: M for meter, K for kilometer), it will reply "area01 ok". Example: Send "area123456 22.353648,113.543678 school,800M". Note: 5 areas at most and the distance between two points can't be less than the total distance in the 2 commands, and different areas can't cover each other.
  • Page 18: Movement Alarm

    name+latitude & longitude" to all the authorized phone number, and send same SMS when goes out of the area. Deactivate Multi-area management 6.19.6.5 Send SMS command "area+password+space+off" to tracker, it will reply"area off ok!" 6.19.7 Movement alarm Set up: when the unit stays immobile in a place for 3-10 minutes with 6.19.7.1.
  • Page 19: Acc Working Alarm

    Cancel: Send SMS “nospeed+password” to deactivate the overspeed alarm. Remark: The recommended speed should be not less than 30km/h. For below that rate, it will be effected the accuracy by GPS signals drift etc. 6.19.9 ACC working alarm This function is disabled as default. To active this function, send 6.19.9.1 "ACC+password"...
  • Page 20: Function Of Remote Controller (Option For Model D )

    after “stop” command, instead, will reply “it will be executed after speed less than 20KM/H”, and stop the car when the speed is less than 20KM/H 6.20.3 Resume the Oil and Power System send “resume+password" to tracker, it will reply "Resume engine succeed", that means vehicle has resume the oil supply.
  • Page 21: Silent Mode

    Press button on the remote controller for 0.5 seconds, the car enters armed state and the siren will beep one time, no SMS reply. If the car is in ignition (ACC is at “ON” position), then the car can’t enter ARM state, and siren keep silent.
  • Page 22: Alarms Under Arm State

    6.25 Alarms under Arm State 6.25.1 ACC alarm The unit will send SMS “ACC alarm+lat/long” to the authorized number at interval of 3 minutes when the engine of the car is turned on, that is the key is rotated to ACC.ON position to start the car in arm state; Siren will sound for 30 seconds,send “disarm+password”...
  • Page 23: Alarm Without Gsm Network Service

    6.26 Alarm without GSM network service When the car is in the place without GSM network service, siren will sound under non-silent mode if alarm is triggered (sensor, ACC), but no SMS alarm will be sent to authorized number. 6.27 Sleep Mode 6.27.1 Sleep by time Send SMS command "sleep+password+space+time"...
  • Page 24: No Sleep Mode

    Calling or SMS can’t awake the tracker .Alarms can be triggered and work normally. The unit will resume to deep sleep by shock sensor mode once alarms stop 6.27.4 No sleep mode Send SMS command”sleep+password+space+off” to tracker device, tracker will reply”sleep off ok”.
  • Page 25: Reset Hardware

    the authorized numbers. For example: Send SMS “check123456” to the tracker device in the vehicle, It will reply following SMS. Power: ON/OFF Battery: 100% GPRS: ON/OFF GPS: OK/NO GPS GSM Signal: 1-32 The higher digit it shows; the stronger of GSM signals it receives.
  • Page 26: Configure Parameters By Usb

    Send command:"gprs+password,1,1" switch to UDP mode. 6.34 Configure parameters by USB Connect the gps tracker to computer with the optional USB cable, find gps tracker’s internal memory and open serial debugging tool the format of text, edit the commands according to the tips. . Note: Filling password correctly is required to configure parameters by USB successfully.
  • Page 27: Gprs User Id And Password Setup

    Notes: 123456 refer to password of tracker and CMNET is the APN of China Mobile (One of GSM Operator in China). 6.35.2 GPRS User ID and password Setup In most countries, the user name and password involving GPRS login are 6.35.2.1 not compulsorily necessary, therefore, the entry can be skipped.
  • Page 28: Less Gprs Traffic

    6.36 Less GPRS traffic Tracker will change to less GPRS traffic mode after parking 5 minutes, 6.36.1 GPRS disconnect and connect again when alarm being triggered or vehicle starts driving. Activate this function: Send "less gprs123456 on", tracker will reply "less 6.36.2 gprs on ok".
  • Page 29: Web Platform And Pc Installation Tracking Software User Manual

    center number must be setup as authorized number 6.38.2 Cancel: Send “nocenternum+password” to tracker, it will reply “no center num ok”. 6.39Web platform and PC installation tracking software user manual based platform www.gpstrackerxy.com. Configuration 6.39.1 202.104.150.75 Port: 9000. Please check “software platform user manual” included in the CD for detailed operation information.
  • Page 30: Cautions

    7 Cautions : Please comply with the instructions to extend the unit life: Keep the unit dry. Any liquid, i.e. rain, moisture, may destroy or damage the inside circuitry. Don’t use & store the unit in dusty places. Don’t put the unit in overheated or overcooled places. Handle carefully.
  • Page 31 SMS reply fail Password incorrect or wrong sms commands format Call without SMS reply or cannot receive alarm Authorized number is wrong or without setting any authorized number fail Remove external power , turn on the device and program again Remote Controller Siren’s voltage is DC12V/24V/1A.

Table of Contents