5-6
Programming RS-485
The majority communicative operation of the RS-485 is in the same of the RS-232.
When the RS-485 precedes the transmission, which needs control the TXC signal, and
the installing, steps are as follows:
Step 1: Enabled TXC
Step 2: Send out data
Step 3: Waiting for data empty
Step 4: Disabled TXC
Note 8: Please refer to the section of the "Serial Ports" in the Chapter 6
"Technical Reference" for the detail description of the COM ports register.
5-6-1 Initialize COM port
Step 1: Initialize COM port in the receiver interrupt mode, and /or transmitter
interrupt mode. (All of the communication protocol buses of the RS-485
are in the same.)
Step 2: Disabled TXC (transmitter control), the bit 0 of the address of offset+4
just sets "0".
Note 9: Control the JetBox system "DTR" signal to the RS-485 TXC
communication.
5-6-1 Send out one character (Transmit)