FRANCO BELGE 154 03 05 Belfort Flueless GN Technical Manual
FRANCO BELGE 154 03 05 Belfort Flueless GN Technical Manual

FRANCO BELGE 154 03 05 Belfort Flueless GN Technical Manual

Belfort flueless gn natural gas (type g20) category i2h

Advertisement

BELFORT
FLUELESS GN
Gas stove - Pr EN 00062012
Model : 154 03 05
Natural gas (type G20)
Category I 2H
Description of the appliance
Installation instructions
Operating instructions
Spare parts
Warranty certificate
Document n°1187-4 ~ 25/02/2005
Technical manual
to be saved
by the user

for future reference

STAUB FONDERIE
SARL with the capital of 6 359 540
Head Office Address
2, rue Saint Gilles
68230 TURCKHEIM
RCS Colmar
SIREN 444 881 953
Address
Administration and manufacturing
BP 73
59660 MERVILLE (FRANCE)
Telephone : 00 333 28 43 43 00
Fax : 00 333 28 43 43 99
Subject to modifications.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 154 03 05 Belfort Flueless GN and is the answer not in the manual?

Questions and answers

Roger
February 5, 2025

Can this fire 154 03 05 be converted to LPG?

Subscribe to Our Youtube Channel

Summary of Contents for FRANCO BELGE 154 03 05 Belfort Flueless GN

  • Page 1: For Future Reference

    BELFORT Document n°1187-4 ~ 25/02/2005 FLUELESS GN Gas stove - Pr EN 00062012 Model : 154 03 05 Technical manual Natural gas (type G20) to be saved Category I 2H by the user for future reference STAUB FONDERIE Description of the appliance SARL with the capital of 6 359 540 Head Office Address Installation instructions...
  • Page 2: Table Of Contents

    Belfort Flueless GN - ref. 154 03 05 FRANCO BELGE congratulates you on your choice. FRANCO BELGE, which has been granted the ISO 9001 certification, guarantees the quality of its appliances and is committed to meet its customers’ needs. FRANCO BELGE, which can boast a 75-year experience in the industry of heating devices, uses state-of-the-art technologies to design and manufacture its whole range of products.
  • Page 3: Description Of The Unit

    Belfort Flueless GN - ref. 154 03 05 Description of the unit This appliance is a gas stove. WARNING This appliance must be installed in compliance with the rules in force by a competent engineer. The appliance must not be operated if the window is cracked or broken. The safety pilot on the burner must not be adjusted and must not be put out of operation.
  • Page 4: Safety Advice

    None of these safety features should be tampered with considered for these conditions conforming to BS 6539 or made un-operable, if replacement parts are needed or BS 6778. then only parts supplied by Franco Belge should be used. Technical manual “1187”...
  • Page 5: Installation Instructions

    Belfort Flueless GN - ref. 154 03 05 Installation instructions 2. Installation instructions The appliance should only be installed by a D E P T H professional engineer, in the strict application of normal practices and all safety precautions. The S H E L .
  • Page 6: Pressure Testing

    Belfort Flueless GN - ref. 154 03 05 Installation instructions 2.5 Connecting the gas supply 2.6 Pressure Testing It is important to ensure that all pipework installed is fitted in accordance with BS6891 and is capable of supplying sufficient gas flow and pressure to meet the minimum pressures quoted in the front of this manual.
  • Page 7: Door Lock

    Belfort Flueless GN - ref. 154 03 05 Installation instructions 2.7 Door Lock Please ensure that when fitting the matrix and coals, that you DO NOT OBSTRUCT THE PILOT FRANCO BELGE accept no responsibility for any injury sustained whilst handling hot ceramics. Instructions for the layout of the prefixed ceramic matrix and loose coals for Belfort Flueless Stove.
  • Page 8 Belfort Flueless GN - ref. 154 03 05 Notes Notes Technical manual “1187”...
  • Page 9: Instructions For User

    Belfort Flueless GN - ref. 154 03 05 Instructions for user 3. Instructions for user The appliance is adjusted and sealed in accordance • Running the appliance at low setting with category (G20) I 2H Ignite permanent pilot and run appliance at “High” A qualified installer must connect and commission setting for a minimum of 10 minutes as shown above.
  • Page 10: Maintenance

    Belfort Flueless GN - ref. 154 03 05 Instructions for user 3.3 Recommandations 3.6 Servicing Instructions • The following outlines only the minimum work that Whenever you ignite the appliance, ensure that the should be performed on an annual basis. This service pilot light’s flame is long enough (2-3 cm) to light the work, like any other work on the appliance, must only be burner rapidly.
  • Page 11 Belfort Flueless GN - ref. 154 03 05 Instructions for user flame should be even across the top of the burner • The thermocouple is not at a high enough before any coals are placed on top. temperature, the pilot light flame is too short. Piezo-electric igniter : The spark between the Check that the injector is not partially blocked.
  • Page 12: Spare Parts

    4. Spare parts Spare partlist So certain parts of your stove must be replaced, use only parts manufactured by Franco Belge. When ordering spare parts, specify the stove type and serial number, including the colour index (on the guarantee or identification plate), the name of the part and the part number.
  • Page 13 Belfort Flueless GN - réf. 154 03 05 Spare parts Figure 4 - Spare parts view Technical manual “1187”...
  • Page 14 § Guarantee certificate § § labour is at the user’s cost. Moreover, if the repair or Legal guarantee replacement of parts covered by the guarantee is found The specifications, dimensions and information shown to be too costly vis-à-vis the price of the appliance, the on our documents are provided for information purposes decision to replace or repair the appliance will be taken only and under no circumstances are binding upon the...

Table of Contents