Technical manual
Net output : 7,7 kW (Wood)
Net output : 6,4 kW (Smokeless fuels)
to be saved
by the user

for future reference

STAUB FONDERIE
Description of the appliance
SARL with the capital of 10 000 000 €
Head Office Address
Installation instructions
2, rue Saint Gilles
68230 TURCKHEIM
RCS Colmar

Operating instructions

SIREN 444 881 953
Address
Spare parts
Administration and manufacturing
BP 73
59660 MERVILLE (FRANCE)
Telephone : 00 333 28 43 43 00
Warranty certificate
Fax : 00 333 28 43 43 99
Subject to modifications.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Savoy Classic 134 08 05 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for FRANCO BELGE Savoy Classic 134 08 05

  • Page 1: For Future Reference

    SAVOY Classic Document n° 986-11 ~ 03/12/2007 Multifuel stove Model : 134 08 05 DIN EN 13240 : 2005-10 Technical manual Net output : 7,7 kW (Wood) Net output : 6,4 kW (Smokeless fuels) to be saved by the user for future reference STAUB FONDERIE Description of the appliance...
  • Page 2: Table Of Contents

    FRANCO BELGE, guarantees the quality of its appliances and is committed to meet its customers’ needs. FRANCO BELGE, which can boast a 80-year experience in the industry of heating devices, uses state-of-the-art technologies to design and manufacture its whole range of products.
  • Page 3: Package

    “Savoy” - ref. 134 08 05 Product information This appliance is meant to burn wood and smokeless fuels safely WARNING Incorrectly installed, this appliance can be dangerous and possibly cause serious accidents. We recommend that you engage the services of a professional engineer for its installation and the regular maintenance requirements.
  • Page 4: Warning To The User

    “Savoy” - ref. 134 08 05 Installation instructions 2. Installation instructions 2.1. Warning to the user Hearth : The appliance must stand on a fireproof hearth. All the local and national regulations, and in It is possible to provide a hearth made of non particular those relating to national and European combusible board/sheet material or tiles at least 12 mm standards, must be observed when installing the...
  • Page 5: Assembly Of Flue Collar

    “Savoy” - ref. 134 08 05 Installation instructions If the chimney has any down draught tendency, due to its position in relation to nearby obstacles, then an anti-down draught cowl must be installed on the chimney or the chimney height must be increased. If the chimney draught is excessive or irregular, a draught stabiliser (barometric damper) must be installed to the connector pipe.
  • Page 6: Mounting The Tray

    “Savoy” - ref. 134 08 05 Installation instructions " 1 - Chimney 2 - Funnel-shape fireproof material 3 - Non combustible register plate 4 - Cleaning access " door 5 - Liner 6 - Non combustible register plate and ventilated air Figure 5 - Chimney connections The connection pipe and any draught stabiliser must have access for cleaning.
  • Page 7: Maintenance Of The Chimney

    “Savoy” - ref. 134 08 05 Installation instructions Figure 8 - Removing the fuel retainer 2.9. Maintenance of the Chimney Very important : To avoid accidents (chimney fire, etc.), regular maintenance should be carried out. If the stove is regularly used, the chimney should be swept several times per year, together with the stovepipe connection section.
  • Page 8: Fuel

    Recommended fuel : The best fuels for use with the and to dry up. Franco Belge “Savoy” are : Note : When the fire is lit for the first time, the stove may Seasoned wood. - hard wood logs that have been cut, give off fumes from the new paint.
  • Page 9: Instruction For Use With Wood

    Leave the lower air control open for a few minutes to re-sprayed / touched up using a stove paint. These allow the initial volatiles in the fuel to burn. products are available from your Franco Belge Dealer. Adjust the lower air control to the desired position (# C).
  • Page 10: Trouble Shooting

    “Savoy” - ref. 134 08 05 Instructions for user 3.8. Trouble Shooting þ : This sign means that you should asked for a qualified engineer to do the work. Problem Probable causes Action Fire difficult to start Wood green, too damp or poor Use the recommended fuel.
  • Page 11: Spare Parts

    “Savoy” - ref. 134 08 05 Spare parts 4. Spare parts When ordering spare parts, specify the stove type and serial number, including the colour index (on the guarantee or identification plate), the name of the part and the part number. Example : Multifuel stove, ref.
  • Page 12 “Savoy” - ref. 134 08 05 Spare parts Figure 11 - Stove - exploded view Technical manual “986”...
  • Page 13 “Savoy” - ref. 134 08 05 Spare parts N° Code Description..Type . . . A ..B ..C ..D ..E ..Qty 309891 RH Front plate .
  • Page 14 § Guarantee certificate § § labour is at the user’s cost. Moreover, if the repair or Legal guarantee replacement of parts covered by the guarantee is found The specifications, dimensions and information shown to be too costly vis-à-vis the price of the appliance, the on our documents are provided for information purposes decision to replace or repair the appliance will be taken only and under no circumstances are binding upon the...

Table of Contents