Belfort Document n° 979-3 EN ~ 28/08/2000 English Oil fired stove Norsk Model : 174 05 05 (EN 1) CAN/CSA approved / ANSI/UL approved Technical manual to be saved by the user for future reference Description of the appliance Installation instructions...
FRANCO BELGE, which has been granted the ISO 9001 certification, guarantees the quality of its appliances and is committed to meet its customers’ needs. FRANCO BELGE, which can boast a 75-year experience in the industry of heating devices, uses state-of-the-art technologies to design and manufacture its whole range of products.
Oil fired stove BELFORT 174 05 05 1. Description of the unit Package 1.1. 200 mm ¤ 1 package. The stove is supplied completely assembled except the four levelling feet that are placed on the burner. Optional equipment 1.2. ¤ Ground vat ¤...
174 05 05 BELFORT Oil fired stove 1.4. Description Flued oil stove with vaporizing burner (Norm EN 1). 1.5. Operating principle Furnace oil is fed to the burner floor (fig. 3) where is it ignited by means of a firestarter (or the Glow-plug ignitor # 6).
174 05 05 BELFORT Oil fired stove Figure 9 - Fitting the tray pipe may be utilized being careful to maintain clearances to any combustible surface. Once the stove has been properly installed the chimney Figure 11 - Gravity or pumped oil supply draught must be checked with a draught meter.
Oil fired stove BELFORT 174 05 05 2.11. Oil flow adjustment The float regulator has been adjusted at the factory and should not need further adjustment. If the burner does not work correctly, check possible causes before readjusting the settings :...
174 05 05 BELFORT Oil fired stove 3. Operating instructions 3.1. Fuel Warning : Your stove is fitted with a specific float regulator for a specific oil. ¤ Kerosene 28 sec. (1,8 cst at 25°C) The fuel oil must be free from any dirt and water which could disturb the stove in operation.
Oil fired stove BELFORT 174 05 05 3.6. Recommendation - remove the filter cover plate located under the float regulator (# 3, fig. 15) with a screwdriver, - remove the tubular filter from the float regulator. Clean The adjustment of the stove has been made at the it with oil using a soft brush, never a wire-brush, factory and checked by your installer.
174 05 05 BELFORT Oil fired stove 3.7. Trouble shooting þ : This sign means that you should asked for a qualified engineer to do the work. PROBLEM TEST SOLUTION SYMPTOM ¤ Very cold chimney. No draught - Leave door ajar until fire has caught.
When ordering spare parts, please indicate : model n°, colour code, description of the part, code of the part. K = 174 05 05 K C = 174 05 05 C Example : Stove 174 05 05 , base 352155 EF N° Code Description .