Malfunction
The Striding Belt is traveling
beyond the tracking limits.

Striding belt not centered.

Striding belt mis-alignment,
but properly tensioned.
Lifepulse Heart Rate System
does not respond or
improper heart rate reading
or "Reading Heart Rate"
appears in the message
center for more than 2
minutes without giving heart
rate reading.
Probable Cause
Striding belt folded over.
Striding belt tension or tracking
needs to be adjusted.
Improper walking/running.
Dirty handlebar sensors.
Inadequate contact with all four
sensors.
User running over 4.5 mph
(7.5kph).
User may have an unusual
heart condition.
Loose connections at display
console and handlebar.
Faulty heart rate sensors..
Faulty display console PCB.
Corrective Action
Refer to "Wax Manual" in the diagnostics
section of this manual to verify if the wax
pump is functioning properly. Replace if
necessary. See How To...Replace Wax
Pump.
Replace the belt and deck. See How To...
Replace Striding Belt.
Adjust striding belt . See How To...Adjust And
Tension The Striding Belt.
Notify Club Manager.
Wipe sensors with a clean soft cloth.
Verify a firm grip of all four sensors (two on
top, two on bottom of handlebar).
For accurate heart rate reading, user must
slow down to less than 4.5 mph (7.5kph).
Have different people grasp sensors to detect
any variance.
Secure connections at display console and
handlebar.
Replace handlebar sensors. See How To...
Replace Heart Rate Kit.
Replace display console PCB. See How To...
Replace Display Console PCB.