 Phase 2 with a sequence of DLE EOT and IDs 
If  the  sending  station  receives  a  sequence  of  DLE  EOT  and  IDs  anytime  during  phase  2,  it  shifts  to 
phase 3 to terminate the message transmission abnormally. Even if the phase 3 terminates normally, 
the transmission results in an abnormal end. 
 
 Phase  2  with  iterated  transmission  of DLE  ENQ  and  IDs  due  to  no  response  or  invalid 
response 
If  the  sending  station  receives  no  response  or  any  invalid  response  from  the  receiving  station  in 
response  to  a  transmission  block  sent,  it  iterates  sending  of  a  sequence  of  DLE  ENQ  and  IDs  at 
0.5-second intervals up to 59 times. 
If the sending station receives a sequence of DLE ACK and IDs before sending the sequence of DLE 
ENQ and IDs 59 times, it continues the subsequent message transmission. 
 