Operation; Engine Check Before Starting; Starting The Engine - Wacker Neuson BPU 3050A Operator's Manual

Wacker neuson vibratory plate operator's manual
Hide thumbs Also See for BPU 3050A:
Table of Contents

Advertisement

Engine check before starting

1. Oil level check
Insert dipstick in oil filler neck, but without screwing in. If oil level is low, fill to the top of the oil filler neck with
high grade Fuchs Titan Unic 10W40 MC oil.
ATTENTION!
2. Dual-air cleander >Dual element type<
Check the air cleaner elements to be sure they are clean and in good condition. Clean or replace the ele-
ments if necessary.
3. Fuel
Use any regular grade automotive gasoline (unleaded gasoline is preferred) with a pump octane rating of
86 or higher.
Never use an oil/gasoline mixture or dirty gasoline: Avoid getting dirt, dust or water in the fuel tank.
Caution:
Gasoline substitutes are not recommended, they may be harmful to the fuel system compo-
nents.

Starting the engine

1. Move the fuel shut-off valve (lever in arrow direction) to the „ON" position.
2. Move the choke lever to the CLOSE position.
Note: If the engine is warm or the air temperature is high, move the control lever away from the CHOKE
postion as soon as the engine starts.
T00857GB
Place machine in horizontal position before checking engine oil level.
12

OPERATION