TROUBLESHOOTING CHART

Complaint
POSSIBLE CAUSE
DOTS IN ANALYSIS
GUIDE INDICATE
"POSSIBLE CAUSE"
Power Failure
Blown Fuse
Unbalanced Power, 3PH
Loose Connection
Shorted or Broken Wires
Open Fan Overload
Faulty Thermostat
Faulty Transformer
Shorted or Open Capacitor
Internal Compressor Overload Open
Shorted or Grounded Compressor
Compressor Stuck
Faulty Compressor Contactor
Faulty Fan Relay
Open Control Circuit
Low Voltage
Faulty Evap. Fan Motor
Shorted or Grounded Fan Motor
Improper Cooling Anticipator
Shortage of Refrigerant
Restricted Liquid Line
Open Element or Limit on Elec. Heater
Dirty Air Filter
Dirty Indoor Coil
Not enough air across Indoor Coil
Too much air across Indoor Coil
Overcharge of Refrigerant
Dirty Outdoor Coil
Noncondensibles
Recirculation of Condensing Air
Infiltration of Outdoor Air
Improperly Located Thermostat
Air Flow Unbalanced
System Undersized
Broken Internal Parts
Broken Valves
Inefficient Compressor
Wrong Type Expansion Valve
Expansion Device Restricted
Oversized Expansion Valve
Undersized Expansion Valve
Expansion Valve Bulb Loose
Inoperative Expansion Valve
Loose Hold-down Bolts
Faulty Reversing Valve
Faulty Defrost Control
Faulty Defrost Thermostat
Flowrator Not Seating Properly
28
COOLING/HP ANALYSIS CHART
No Cooling
Unsatisfactory Cooling/Heating
• •
• •
• • • • • •
• •
• •
• • • •
• •
• •
• •
• •
• •
• •
• •
• • •
• • •
• • •
Cooling or Heating Cycle (Heat Pump)
System
Operating
Pressures
• •
• •
• •
• •
• •
• •
• •
• •
• •
• •
• •
♦ ♦ ♦
♦ ♦ ♦
♦ ♦ ♦ ♦ ♦
♦ ♦ ♦ ♦ ♦ ♦ ♦
• •
Heating Cycle Only (Heat Pump)
Test Method
Remedy
Test Voltage
Inspect Fuse Size & Type
Test Voltage
Inspect Connection - Tighten
Test Circuits With Ohmmeter
Test Continuity of Overload
Test Continuity of Thermostat & Wiring
Check Control Circuit with Voltmeter
Test Capacitor
Test Continuity of Overload
Test Motor Windings
Use Test Cord
Test Continuity of Coil & Contacts
Test Continuity of Coil And Contacts
Test Control Circuit with Voltmeter
Test Voltage
Repair or Replace
Test Motor Windings
Check Resistance of Anticipator
Test For Leaks, Add Refrigerant
Remove Restriction, Replace Restricted Part
Test Heater Element and Controls
Inspect Filter-Clean or Replace
Inspect Coil - Clean
Check Blower Speed, Duct Static Press, Filter
Reduce Blower Speed
Recover Part of Charge
Inspect Coil - Clean
Recover Charge, Evacuate, Recharge
Remove Obstruction to Air Flow
Check Windows, Doors, Vent Fans, Etc.
Relocate Thermostat
Readjust Air Volume Dampers
Refigure Cooling Load
Replace Compressor
Test Compressor Efficiency
Test Compressor Efficiency
Replace Valve
Remove Restriction or Replace Expansion Device
Replace Valve
Replace Valve
Tighten Bulb Bracket
Check Valve Operation
Tighten Bolts
Replace Valve or Solenoid
Test Control
Test Defrost Thermostat
Check Flowrator & Seat or Replace Flowrator
S-1
S-1
S-1
S-2, S-3
S-2, S-3
S-17A
S-3
S-4
S-15
S-17A
S-17B
S-17D
S-7, S-8
S-7
S-4
S-1
S-16
S-16
S-3B
S-101,103
S-112
S-26,S-27
S-200
S-200
S-113
S-114
S-115
S-104
S-104
S-110
S-110
S-105
S-110
S-21, 122
S-24
S-25
S-111

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents