Ash 13 Seer: Heating Specifications - Goodman GSH Series Service Instructions Manual

Split system air conditioners, split system heat pumps with r-22 refrigerant blowers, coils, & accessories
Table of Contents

Advertisement

HEATING SPECIFICATIONS
Model: GHS140181A* / CA*F3131B6A*+TXV / MBR800**-1
Condition: 600 CFM Indoor Air @ 70°F DB
Basic Unit without
Outdoor
Auxiliary Heat
Ambient
°F.
capacity
btuh
c.o.p.
65
22.63
4.23
21.42
4.09
60
55
20.16
3.93
50
18.85
3.75
17.44
3.54
45
40
16.20
3.36
35
14.94
3.16
30
13.55
2.88
25
12.51
2.72
20
11.52
2.56
15
10.47
2.39
10
9.40
2.19
5
8.33
1.99
0
7.26
1.78
-5
6.20
1.56
5.08
1.31
-10
Model: GSH140301A* / CA*F3636B6A*+TXV / MBR1200**-1
Condition: 1,080 CFM Indoor Air @ 70°F DB
Basic Unit without
Outdoor
Auxiliary Heat
Ambient
°F.
capacity
btuh
c.o.p.
65
34.69
4.53
60
32.84
4.37
55
30.91
4.19
50
28.90
4.00
45
26.74
3.77
40
24.84
3.57
35
22.91
3.36
30
20.93
2.97
25
19.32
2.80
20
17.79
2.63
15
16.18
2.45
10
14.51
2.25
5
12.87
2.04
0
11.22
1.82
-5
9.57
1.59
-10
7.84
1.34
Model: GSH140421A* / CA*F4860D6A*+TXV / MBR2000**-1
Condition: 1,400 CFM Indoor Air @ 70°F DB
Basic Unit without
Outdoor
Auxiliary Heat
Ambient
°F.
capacity
btuh
c.o.p.
65
49.78
4.56
60
47.12
4.39
55
44.35
4.21
50
41.46
4.02
45
38.37
3.79
40
35.64
3.59
35
32.87
3.38
30
31.24
3.16
25
28.84
2.98
20
26.56
2.81
15
24.15
2.61
10
21.67
2.40
5
19.21
2.17
0
16.75
1.94
-5
14.29
1.70
-10
11.71
1.43
Capacity of Unit
With KW of Auxiliary heat
19.2
4.8
9.6
14.4
39.008
55.391
71.7732
88.156
37.802
54.185
70.5672
86.950
36.542
52.925
69.3072
85.690
35.228
51.611
67.9932
84.376
33.824
50.207
66.5892
82.972
32.582
48.965
65.3472
81.730
31.322
47.705
64.0872
80.470
29.933
46.315
62.6975
79.080
28.889
45.271
61.6535
78.036
27.899
44.281
60.6638
77.046
26.855
43.237
59.6198
76.002
25.778
42.161
58.5432
74.926
24.713
41.095
57.4775
73.860
23.647
40.029
56.4117
72.794
22.581
38.964
55.346
71.728
21.461
37.843
54.2258
70.608
Capacity of Unit
With KW of Auxiliary heat
4.8
9.6
14.4
19.2
51.076
67.458
83.8404
100.223
49.226
65.609
81.9912
98.374
47.294
63.677
80.0592
96.442
45.280
61.662
78.0444
94.427
43.127
59.509
75.8916
92.274
41.222
57.605
73.987
90.370
39.290
55.673
72.0552
88.438
37.311
53.694
70.0763
86.459
35.699
52.081
68.4638
84.846
34.170
50.553
66.9352
83.318
32.558
48.940
65.3227
81.705
30.895
47.277
63.660
80.042
29.249
45.631
62.0137
78.396
27.603
43.985
60.3676
76.750
25.957
42.339
58.7215
75.104
24.227
40.609
56.9914
73.374
Capacity of Unit
With KW of Auxiliary heat
4.8
9.6
14.4
19.2
66.160
82.542
98.9244 115.307
63.506
79.889
96.2712 112.654
60.734
77.117
93.4992 109.882
57.844
74.226
90.6084 106.991
54.755
71.137
87.5196 103.902
52.022
68.405
84.7872 101.170
49.250
65.633
82.0152
98.398
47.627
64.009
80.3919
96.774
45.220
61.602
77.9846
94.367
42.938
59.320
75.7027
92.085
40.531
56.913
73.2954
89.678
38.048
54.430
70.8129
87.195
35.591
51.973
68.3554
84.738
33.133
49.516
65.898
82.280
30.676
47.058
63.4405
79.823
28.093
44.475
60.8577
77.240
M ODEL GSH140601A* / CA*F4860D6A* +TXV / M BR2000**-1
Condition: 1,850 CFM Indoor Air @ 70°F DB
Basic Unit without
Outdoor
Auxiliary Heat
Ambient
°F.
capacity
btuh
c.o.p.
65
69.14
4.81
60
65.45
4.65
55
61.60
4.46
50
57.59
4.26
45
53.30
4.03
40
49.50
3.82
35
45.65
3.60
30
41.02
3.24
25
37.86
3.06
20
34.87
2.89
15
31.70
2.69
10
28.45
2.47
5
25.22
2.25
0
21.99
2.01
-5
18.77
1.77
-10
15.38
1.49
M odel: GSH140241A* / CA*F3636B6A*+TXV / M BR800**1
Condition: 850 CFM Indoor Air @ 70°F DB
Basic Unit without
Outdoor
Auxiliary Heat
Ambient
°F.
capacity
btuh
c.o.p.
65
30.17
4.30
60
28.56
4.14
55
26.88
3.98
50
25.13
3.79
45
23.26
3.58
40
21.60
3.39
35
19.92
3.19
30
18.76
2.91
25
17.32
2.74
20
15.95
2.58
15
14.50
2.40
10
13.01
2.21
5
11.54
2.00
0
10.06
1.79
-5
8.58
1.57
-10
7.03
1.32
Model: GSH140361A* / CA*F4860C6A*+TXV / MBR1600**-1
Condition: 1,065 CFM Indoor Air @ 70°F DB
Basic Unit without
Outdoor
Auxiliary Heat
Ambient
°F.
capacity
btuh
c.o.p.
65
43.49
4.37
60
41.17
4.22
55
38.75
4.04
50
36.23
3.86
45
33.53
3.64
40
31.14
3.45
35
28.72
3.25
30
26.94
2.98
25
24.87
2.82
20
22.90
2.65
15
20.82
2.46
10
18.68
2.26
5
16.56
2.06
0
14.44
1.84
-5
12.33
1.61
-10
10.10
1.35
Model: GSH140481A* / CA*F4860D6A* +TXV / MBR2000**-1
Condition: 1,550 CFM Indoor Air @ 70°F DB
Basic Unit without
Outdoor
Auxiliary Heat
Ambient
°F.
capacity
btuh
c.o.p.
65
57.82
4.21
60
54.74
4.07
55
51.52
3.90
50
48.16
3.72
45
44.57
3.52
40
41.40
3.33
35
38.18
3.14
30
37.68
3.05
25
34.77
2.88
20
32.02
2.71
15
29.12
2.52
10
26.12
2.32
5
23.16
2.10
0
20.20
1.88
-5
17.24
1.65
-10
14.12
1.38
Capacity of Unit
With KW of Auxiliary heat
19.2
4.8
9.6
14.4
85.517
101.900 118.282
134.665
81.832
98.215
114.597
130.980
77.982
94.365
110.747
127.130
73.967
90.350
106.732
123.115
69.677
86.060
102.442
118.825
65.882
82.265
98.647
115.030
62.032
78.415
94.797
111.180
57.404
73.787
90.169
106.552
54.244
70.626
87.009
103.391
51.248
67.630
84.013
100.395
48.087
64.470
80.852
97.234
44.828
61.210
77.593
93.975
41.601
57.984
74.366
90.749
38.375
54.757
71.140
87.522
35.149
51.531
67.913
84.296
31.757
48.140
64.522
80.905
C apacity of Unit
W ith KW of Auxiliary heat
4.8
9.6
14.4
19.2
46.550
62.933
79.315
95.698
44.942
61.325
77.707
94.090
43.262
59.645
76.027
92.410
41.510
57.893
74.275
90.658
39.638
56.021
72.403
88.786
37.982
54.365
70.747
87.130
36.302
52.685
69.067
85.450
35.146
51.528
67.911
84.293
33.700
50.083
66.465
82.847
32.330
48.712
65.095
81.477
30.884
47.267
63.649
80.031
29.393
45.776
62.158
78.541
27.918
44.300
60.682
77.065
26.442
42.824
59.207
75.589
24.966
41.348
57.731
74.113
23.415
39.797
56.180
72.562
Capacity of Unit
With KW of Auxiliary heat
19.2
4.8
9.6
14.4
59.875
76.257
92.6394
109.022
57.556
73.939
90.3212
106.704
55.134
71.517
87.8992
104.282
52.609
68.991
85.3734
101.756
49.910
66.292
82.6746
99.057
47.522
63.905
80.2872
96.670
45.100
61.483
77.8652
94.248
43.325
59.707
76.0895
92.472
41.249
57.631
74.0137
90.396
39.281
55.664
72.046
88.428
37.205
53.588
69.9701
86.353
35.065
51.447
67.8295
84.212
32.946
49.328
65.7104
82.093
30.827
47.209
63.5914
79.974
28.708
45.090
61.4723
77.855
26.480
42.863
59.2451
75.628
Capacity of Unit
With KW of Auxiliary heat
19.2
4.8
9.6
14.4
74.204
90.587
106.969
123.352
71.122
87.505
103.887
120.270
67.902
84.285
100.67
117.050
64.544
80.927
97.3092
113.692
60.956
77.339
93.7212
110.104
57.782
74.165
90.5472
106.930
54.562
70.945
87.3272
103.710
54.058
70.440
86.8225
103.205
51.155
67.537
83.9198
100.302
48.403
64.786
81.1682
97.551
45.501
61.883
78.2654
94.648
42.507
58.890
75.272
91.654
39.544
55.926
72.3087
88.691
36.581
52.963
69.3455
85.728
33.617
50.000
66.3823
82.765
30.503
46.885
63.2679
79.650
23

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents