Goodman GSC13 SEER Technical Manual

Goodman GSC13 SEER Technical Manual

Gsc13 seer condensing units

Advertisement

GSC13 SEER Condensing Units
Refer to Service Manual RS6100004 for installation, operation, and troubleshooting information.
All safety information must be followed as provided in the Service Manual.
Refer to the appropriate Parts Catalog for part number information.
Models listed on page 3.
This manual is to be used by qualified, professionally trained HVAC technicians only.
Goodman does not assume any responsibility for property damage or personal injury due
to improper service procedures or services performed by an unqualified person.
Copyright © 2011 Goodman Manufacturing
TECHNICAL MANU
TECHNICAL MANU
TECHNICAL MANU AL
TECHNICAL MANU
TECHNICAL MANU
(Shipped Without Refrigerant Charge)
Company, L.P.
AL
AL
AL
AL
RT6112017r5
December 2011

Advertisement

Table of Contents
loading

Summary of Contents for Goodman GSC13 SEER

  • Page 1 Models listed on page 3. This manual is to be used by qualified, professionally trained HVAC technicians only. Goodman does not assume any responsibility for property damage or personal injury due RT6112017r5 to improper service procedures or services performed by an unqualified person.
  • Page 2: Product Identification

    Disconnect ALL power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury or death. Goodman will not be responsible Installation and repair of this unit WARNING WARNING...
  • Page 3 WARNING that is not design certified by damage, personal injury, or death, Goodman for use with this unit. do not store combustible materials or use gasoline or Serious property damage, personal injury, reduced unit other flammable liquids or vapors in the vicinity of this performance and/or hazardous conditions may result appliance.
  • Page 4: Product Design

    PRODUCT DESIGN The GSC13 SEER models are shipped with a nitrogen hold- ing charge only and are available in 1 1/2 through 5 ton sizes. They are designed for 208/230 volt single phase applications. Select GSC 3 phase models are available in 208-230V 3 phase and 460v 3 phase.
  • Page 5 PRODUCT DESIGN GSC130[18-60]** Dimensions Dimensions Model W x D x H GSC130181BB/DA/FA 26 x 26 x 27½ GSC130241DB/EA/FA 26 x 26 x 27½ GSC130301DB/E* 26 x 26 x 30¼ GSC130361FB/GA 29 x 29 x 30¼ GSC130421BB 29 x 29 x 30¼ GSC130481BB 29 x 29 x 34¼...
  • Page 6 CONDENSING UNIT SPECIFICATIONS GSC130[18-36]1* GSC130[18-24]1* GSC130181BB GSC130181DA GSC130181FA GSC130241DB GSC130241EA GSC130241FA Nominal Cooling Capacity, BTUH 18,000 18,000 18,000 24,000 24,000 24,000 Compressor R.L. Amps 10.8 L.R. Amps Condenser Fan Motor Horsepower F.L. Amps Refrigerant Line Size Liquid Line, Inches O.D. 3/8"...
  • Page 7 CONDENSING UNIT SPECIFICATIONS GSC130[42-60]1* GSC130[42-60]1* GSC130421BB GSC130481BB GSC130601CB Nominal Cooling Capacity, BTUH 42,000 48,000 57,000 Compressor R.L. Amps 19.2 17.9 19.9 L.R. Amps Condenser Fan Motor Horsepower F.L. Amps Refrigerant Line Size Liquid Line, Inches O.D. 3/8" 3/8" 3/8" Suction Line, Inches O.D. 1-1/8"...
  • Page 8 CONDENSING UNIT SPECIFICATIONS GSC130363B* GSC130483B* GSC130603B* GSC130484B* GSC130604B* Nominal Cooling Capacity, BTUH 36,000 48,000 57,000 45,500 55,500 Compressor R.L. Amps 12.4 14.7 L.R. Amps 65.5 88.0 91.0 44.0 50.0 Condenser Fan Motor Horsepower F.L. Amps Refrigerant Line Size Liquid Line, Inches O.D. 3/8"...
  • Page 9 COOLING PERFORMANCE DATA GSC130181BB...
  • Page 10 COOLING PERFORMANCE DATA GSC130181BB...
  • Page 11 COOLING PERFORMANCE DATA GSC130181DA...
  • Page 12 COOLING PERFORMANCE DATA GSC130181DA...
  • Page 13 GSC130181FA COOLING PERFORMANCE DATA...
  • Page 14 COOLING PERFORMANCE DATA GSC130181FA...
  • Page 15 GSC130241DB COOLING PERFORMANCE DATA...
  • Page 16 GSC130241DB COOLING PERFORMANCE DATA...
  • Page 17 COOLING PERFORMANCE DATA GSC130241EA...
  • Page 18 COOLING PERFORMANCE DATA GSC130241EA...
  • Page 19 COOLING PERFORMANCE DATA GSC130241FA...
  • Page 20 GSC130241FA COOLING PERFORMANCE DATA...
  • Page 21 COOLING PERFORMANCE DATA GSC130301DB...
  • Page 22 GSC130301DB COOLING PERFORMANCE DATA...
  • Page 23 COOLING PERFORMANCE DATA GSC130301E*...
  • Page 24 COOLING PERFORMANCE DATA GSC130301E*...
  • Page 25 COOLING PERFORMANCE DATA GSC130361FB...
  • Page 26 COOLING PERFORMANCE DATA GSC130361FB...
  • Page 27 COOLING PERFORMANCE DATA GSC130361GA...
  • Page 28 COOLING PERFORMANCE DATA GSC130361GA...
  • Page 29 COOLING PERFORMANCE DATA GSC130421BB...
  • Page 30 COOLING PERFORMANCE DATA GSC130421BB...
  • Page 31 COOLING PERFORMANCE DATA GSC130481BB...
  • Page 32 COOLING PERFORMANCE DATA GSC130481BB...
  • Page 33 GSC130601CB COOLING PERFORMANCE DATA...
  • Page 34 GSC130601CB COOLING PERFORMANCE DATA...
  • Page 35 COOLING PERFORMANCE DATA GSC130363BB...
  • Page 36 COOLING PERFORMANCE DATA GSC130363BB...
  • Page 37 COOLING PERFORMANCE DATA GSC130483BB...
  • Page 38 COOLING PERFORMANCE DATA GSC130483BB...
  • Page 39 GSC130603BB COOLING PERFORMANCE DATA...
  • Page 40 COOLING PERFORMANCE DATA GSC130603BB...
  • Page 41 COOLING PERFORMANCE DATA GSC130484BB...
  • Page 42 COOLING PERFORMANCE DATA GSC130484BB...
  • Page 43 COOLING PERFORMANCE DATA GSC130604BB...
  • Page 44 GSC130604BB COOLING PERFORMANCE DATA...
  • Page 45: Cooling Performance Data

    COOLING PERFORMANCE DATA PERFORMANCE TEST All data based upon listed indoor dry bulb temperature. .00 inches external static pressure on coil of outdoor section. Indoor air cubic feet per minute (CFM) as listed in the Performance Data Sheets: If conditions vary from this, results will change as follows: As indoor dry bulb temperatures increase, a slight increase will occur in indoor air temperature drop (Delta T).
  • Page 46: Wiring Diagrams

    WIRING DIAGRAMS GSC130[18-60]1** HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
  • Page 47 WIRING DIAGRAMS GSC130[18-60]1** HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
  • Page 48 WIRING DIAGRAMS GSC130[36/48/60]3B* - GSC130[48/60]4B* HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.

Table of Contents