Kaco Powador 3200 Operating Instructions Manual page 52

Hide thumbs Also See for Powador 3200:
Table of Contents

Advertisement

M a in tenance/Tro u b le s ho ot in g
Authorised electrician
Status
Display
OS 63
Measured values
OS 64
Measured values
FS
66
Instrument
transformer fault
FS
Confi g. error
Invalid CRC
Table 7:
Operating statuses and fault messages on the display
Page 52
Explanation
!
P(f)/frequency-dependent power
reduction: Frequency-dependent
power reduction will be activated
when the BDEW (German Association
of Energy and Water Industries)
Medium Voltage Directive goes into
eff ect. Power reduction starts at a
frequency of 50.2 Hz.
Output current limiting: The AC
current is limited once the specifi ed
maximum value has been reached.
Plausibility test of ADC test between
ARM and DSP has failed
The checksum of the loaded confi g.
fi le does not match the checksum
in the EEPROM. This means that
the EEPROM data originate from a
diff erent confi g. fi le.
Action
-
-
 In case of
repeated
occurrence:
Notify your
authorised
electrician.
 Notify
authorised
electrician /
KACO Service
Operating Instructions Powador 3200-6600_EN
By
-
-
E
E/K