Summary of Contents for Kaco blueplanet 3.0 NX1 M2
Page 1
KACO blueplanet 3.0 NX1 M2 KACO blueplanet 3.7 NX1 M2 KACO blueplanet 4.0 NX1 M2 KACO blueplanet 5.0 NX1 M2 Quick installation guide English version Authorized electrician Important safety instructions These instructions form part of the product and must be observed. They must also be stored in a place which is always freely...
The app is available to download on Apple App Store and Google Play Store (currently the app for Android is only available for download on KACO website under the software download section of the NX1 inverters. It will be available in Play Store soon).
5 Wait for the result of the network configuration. Fig. 6: Home page Fig. 7: Scan QR code KACO blueplanet 3.0 NX1 M2 KACO blueplanet 3.7 NX1 M2 KACO blueplanet 4.0 NX1 M2 KACO blueplanet 5.0 NX1 M2 Page 2...
Page 5
Wi-Fi stick’s serial number in your WLAN list. You can connect to the Wi-Fi stick hotspot using the registration code on the label as the password. Page 3 KACO blueplanet 3.0 NX1 M2 KACO blueplanet 3.7 NX1 M2 KACO blueplanet 4.0 NX1 M2 KACO blueplanet 5.0 NX1 M2...
You have removed a single inverter/multiple inverters to the Wi-Fi stick. › You have replaced a single inverter/multiple inverters to the Wi-Fi stick. KACO blueplanet 3.0 NX1 M2 KACO blueplanet 3.7 NX1 M2 KACO blueplanet 4.0 NX1 M2 KACO blueplanet 5.0 NX1 M2 Page 6...
The appropriate voltage range and frequency range for starting can be set according to the requirements of the local grid company. Fig. 18: Parameter settings for starting KACO blueplanet 3.0 NX1 M2 KACO blueplanet 3.7 NX1 M2 KACO blueplanet 4.0 NX1 M2 KACO blueplanet 5.0 NX1 M2 Page 8...
3. The first threshold tripping time ≤ The second threshold tripping time ≤ The third threshold tripping time Fig. 19: Grid voltage protection Page 9 KACO blueplanet 3.0 NX1 M2 KACO blueplanet 3.7 NX1 M2 KACO blueplanet 4.0 NX1 M2 KACO blueplanet 5.0 NX1 M2...
3. The first threshold tripping time ≤ The second threshold tripping time ≤ The third threshold tripping time Fig. 20: Grid frequency protection KACO blueplanet 3.0 NX1 M2 KACO blueplanet 3.7 NX1 M2 KACO blueplanet 4.0 NX1 M2 KACO blueplanet 5.0 NX1 M2 Page 10...
The grid company maybe requires reduction of active power on set point. You can set ‘Active power limit’ according to the requirement. Fig. 22: Power limit KACO blueplanet 3.0 NX1 M2 KACO blueplanet 3.7 NX1 M2 KACO blueplanet 4.0 NX1 M2 KACO blueplanet 5.0 NX1 M2 Page 12...
Min. delay time for active power release is the delay time that the active power can increase after the frequency below reset Page 13 KACO blueplanet 3.0 NX1 M2 KACO blueplanet 3.7 NX1 M2 KACO blueplanet 4.0 NX1 M2 KACO blueplanet 5.0 NX1 M2...
Min. delay time for active power release is the delay time that the active power can increase after the voltage below U reset Page 15 KACO blueplanet 3.0 NX1 M2 KACO blueplanet 3.7 NX1 M2 KACO blueplanet 4.0 NX1 M2 KACO blueplanet 5.0 NX1 M2...
The ‘Time constant 3(τ)’ is three time constant of the filter and is the time until 95% of the nominal value is reached. Fig. 25: Reactive running mode Page 17 KACO blueplanet 3.0 NX1 M2 KACO blueplanet 3.7 NX1 M2 KACO blueplanet 4.0 NX1 M2 KACO blueplanet 5.0 NX1 M2...
Activation threshold as a percentage of U corresponds to ‘lock-in’ voltage Deactivation threshold as a percentage of U corresponds to ‘lock-out’ voltage KACO blueplanet 3.0 NX1 M2 KACO blueplanet 3.7 NX1 M2 KACO blueplanet 4.0 NX1 M2 KACO blueplanet 5.0 NX1 M2 Page 18...
3.2.14 Inverter reactive power setting: fixed Q The fixed reactive power as a percentage of P can be set. Fig. 28: Fixed Q Page 19 KACO blueplanet 3.0 NX1 M2 KACO blueplanet 3.7 NX1 M2 KACO blueplanet 4.0 NX1 M2 KACO blueplanet 5.0 NX1 M2...
You have removed a single inverter/multiple inverters to the Wi-Fi stick. › You have replaced a single inverter/multiple inverters to the Wi-Fi stick. KACO blueplanet 3.0 NX1 M2 KACO blueplanet 3.7 NX1 M2 KACO blueplanet 4.0 NX1 M2 KACO blueplanet 5.0 NX1 M2 Page 22...
The sampling time. Error code Displays the current error code, if one is present. Fig. 15: Inverter real time data Page 23 KACO blueplanet 3.0 NX1 M2 KACO blueplanet 3.7 NX1 M2 KACO blueplanet 4.0 NX1 M2 KACO blueplanet 5.0 NX1 M2...
» The whole process takes about 10 minutes. Choose the inverter and choose the firmware path in your smart device. KACO blueplanet 3.0 NX1 M2 KACO blueplanet 3.7 NX1 M2 KACO blueplanet 4.0 NX1 M2 KACO blueplanet 5.0 NX1 M2 Page 24...
Page 27
The whole process will take approximately 10 minutes. After 10 minutes, you can check the firmware with the app. Page 25 KACO blueplanet 3.0 NX1 M2 KACO blueplanet 3.7 NX1 M2 KACO blueplanet 4.0 NX1 M2 KACO blueplanet 5.0 NX1 M2...
Need help?
Do you have a question about the blueplanet 3.0 NX1 M2 and is the answer not in the manual?
Questions and answers