I n sta l li ng the Inve rt e r
Authorised electrician
Connecting the PV generator
1.
Unscrew the cable fi ttings.
2. Remove the outer cladding of the DC cables.
3.
Insert the DC leads through the cable fi ttings into the connection area.
4. Strip the insulation from the DC cables.
5.
Connect the ends of the cables to the DC connections.
6. Check that all connected cables are tightly seated.
7.
Tighten the cable fi ttings.
8. The requirements of protection rating IP54 are met by closing the unused cable fi ttings with blind caps.
»
The inverter is connected to the PV generator.
7.2.2.3
Connection of the PV generator with solar plug connector
Connecting the PV generator
1.
Screw the cable fi ttings from the base plate.
2. Insert the solar plug connector through the opening from the outside and lock from the inside with black
plastic nuts.
3.
Remove the outer cladding of the DC cables.
4. Insert the DC leads into the connection area through the solar connectors.
5.
Strip the insulation from the DC cables.
6. Connect the ends of the cables to the DC connections.
7.
Check that all connected cables are tightly seated.
8. Tighten the cable fi ttings.
9. The requirements of protection rating IP54 are met by closing the unused cable fi ttings with blind caps.
»
The inverter is connected to the PV generator.
Figure 15: Assembling the solar plug connection