C onfig ura tion an d O pe rat i on
Authorised electrician
Country-
Menu
spec. setting
level
1
2
3
3
All countries
1
2
3
3
DE
NSp.
1
2
3
3
1
2
3
3
DE
CZ
TAH BG
FR
1
2
3
3
AU
ES
PT
IL
1
2
3
3
GB
GR
ES
1663
IT
CEI021
DE
NSp.
1
2
3
3
All countries
1
2
3
3
1
2
3
3
DE
NSp.
Page 42
Display/
settings
"Parameters" menu
Selecting country
with grid type and
directive
Overvoltage
Max. line voltage EN
50160
Voltage drop
between meter and
inverter
Voltage switch-off
Minimum/maximum
grid frequency
Minimum/maximum
grid frequency
Connect time
Action in this menu/meaning
Only service technicians are permitted to make changes
in the parameter menu.
↻ You are in menu level "1".
↻ The unit name is displayed.
 Press "2" for at least 15 seconds to open menu level
3.
The default setting is used if "no" is selected.
1.
Enter the four-digit password using key "2". The
password is unit-specifi c.
2. Confi rm what you have entered using key "1".
3.
Set the desired country setting.
 Select the type of grid applicable to the use of the
inverter.
NOTE: This option infl uences the country-specifi c
operating settings of the inverter. Please consult KACO
service for further information.
 The overvoltage switch-off can be optionally
password-protected.
 Specify the switch-off threshold for overvoltage
shutdown.
The 10-minute average for the measured voltage as
per EN50160 is used.
The grid voltage is averaged over ten minutes. If the
defi ned value is exceeded, the inverter is disconnected
from the grid.
 Set voltage threshold.
The voltage drop between the inverter and the grid-
feed meter is added to the limit value that was set for
grid shutdown according to EN 50160. The limit value
can be set from 0 to 11 V in 1 V increments.
 Specify the switch-off value for the voltage drop (0
to 11 V).
If the grid frequency exceeds or drops below the
confi gured values, the inverter switches off . The
minimum switch-off threshold can be set in 1 V
increments.
 Confi gure the switch-off values for undervoltage
and overvoltage.
Shows the minimum/maximum allowable grid
frequency.
Shows the minimum/maximum allowable grid
frequency.
 Set limit values for underfrequency and
overfrequency switch-off in 0.1 Hz increments
 Set connect time for grid monitoring after fault or
device start in 10 sec. increments.
Operating Instructions Powador 3200-6600_EN