T echni ca l Dat a
Input levels
Max. recommended PV generator power [W]
DC MPP range from [V] to [V]
Operating range from [V] to [V]
Starting voltage [V]
Open circuit voltage [V]
Max. rated current [A]
Max. power per tracker [W]
Number of strings
Number of MPP controls
Polarity safeguard
Output levels
Rated power [VA]
Max. rated power [VA]
Grid voltage [V]
Rated current [A]
Max. rated current [A]
Rated frequency [Hz]
cos phi
Number of feed-in phases
General electrical data
Max. effi ciency [%]
European effi ciency [%]
Internal consumption: night [W]
Feed-in starts at [W]
Circuit design
Transformer unit
Grid monitoring
CE conformity
Table 2:
Electrical data
Page 16
5300 supreme
5 300
350...510
600
14.5
5 250
Short-circuit diode
4 400
4 800
19.1
20.9
0.80 over-excited ... 0.80 under-excited
97.2
(97.6 @ 9 kHz)
96.6
(97.1 @ 9 kHz)
Transformerless
Country-specifi c
5500
6600
5 500
350...600
350...600
370 to 500
410
800
15.2
6 000
3
1
4 600
5 060
190 - 264
20
22
50 / 60
1
96.3
95.7
0
Approx. 35
No
yes
Operating Instructions Powador 3200-6600_EN
6 600
800
18
6 800
5 500
6 000
23.9
26
96.3
95.8