Clearances To Combustibles - Quadra-Fire VOYAGEUR-MBK Installation Manual

Wood insert
Hide thumbs Also See for VOYAGEUR-MBK:
Table of Contents

Advertisement

VOYAGEUR
B. Clearances to Combustibles
47-3/16
1199mm
See next page for thermal protection
In Canada a full length 6 inch (152mm) S635 flue liner required as per ULC S628.
In USA a minimum 5 ft length (1.82m), 6 inch (152mm) diameter flue liner is required as per UL 1482.
WARNING
Fire Risk.
• Comply with all minimum clearances to
combustibles as specified.
• Failure to comply may cause house fire.
8
31-1/4
794mm
USA 18-3/4
CANADA
22-3/4 (578mm)
12in max
MANTEL
USA 17-7/16
CANADA 19-7/16 (494mm)
HEARTH EXTENSION
requirements
United States and Canada (UL and ULC)
TOP TRIM (3/4" max)
21-1/4
540mm
HEARTH
EXTENSION
NOTE: Keep Ashlip
Clear of Ashes
NOTE: Hearth Rug may be used in Suggested Area
NOTE: Clearances may only be reduced by
means approved by the regulatory authority
having jurisdiction
7063-513
40-3/16
1021mm
March 17, 2014