Figure 23.1
4. Remove the 2 screws at the top of the control
plate. Push the bottom of the control plate to the
inside of the appliance and partially remove the
control plate assembly.
Figure 23.2
5. Locate the black and white wires that are part of
the power cord and disconnect those wires from
the wire harness.
Figure 23.3
March 17, 2014
White Wire
Black Wire
Blower Access
Assembly
Grille hinges
downward
Remove Screws &
Pull Access Assembly
away from Insert
Figure 23.4
6. Remove the screw that is holding the ground lug
to the control plate.
Figure 23.5
7. Use needle nose pliers to remove the strain relief
that protects the power cord from the control plate.
Placement Slot
Hold Down
Bracket
Remove Screws from Hold Down
Bracket and Pull Blower Assembly
Forward. Do not Remove Blower from
the Hold Down Bracket
7063-513
Green Grounding
Wire
Remove Screw
Snap Disc Bracket
Blower Control Plate