Quadra-Fire VOYAGEUR-MBK Installation Manual
Quadra-Fire VOYAGEUR-MBK Installation Manual

Quadra-Fire VOYAGEUR-MBK Installation Manual

Voyageur wood insert automatic combustion control (acc)
Hide thumbs Also See for VOYAGEUR-MBK:

Advertisement

Quick Links

INSTALLER: Leave this manual with party responsible for use and operation.
OWNER: Retain this manual for future reference.
VOYAGEUR WOOD INSERT
AUTOMATIC COMBUSTION CONTROL
MODEL(S):
VOYAGEUR-MBK
VOYAGEUR-PMH
Installation and service of this appliance should be performed by
qualified personnel. Hearth & Home Technologies recommends
HHT Factory Trained or NFI certified professionals.
1
Installation Manual
Installation & Appliance Set-Up
NOTICE: DO NOT DISCARD THIS MANUAL
(ACC)
If the information in these instructions is not
followed exactly, a fire could result causing
property damage, personal injury, or death.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
Do not over fire - If appliance or chimney connector
glows, you are over firing. Over firing will void your
warranty.
Comply with all minimum clearances to combustibles
as specified. Failure to comply may cause house
fire.
HOT SURFACES!
Glass and other surfaces are hot during
operation AND cool down.
Hot glass and appliance will cause burns.
Do not touch glass until it is cooled
Use leather gloves when reloading fuel
NEVER allow children to touch glass
Keep children away
CAREFULLY SUPERVISE children in same room as
appliance.
Alert children and adults to hazards of high
temperatures
High temperatures may ignite clothing or other
flammable materials.
Keep clothing, furniture, draperies and other
flammable materials away.
Fire Risk.
For use with solid wood fuel only.
Other fuels may over fire and generate
poisonous gases (i.e. carbon monoxide).
To obtain a French translation of this manual, please contact
your dealer or visit
www.quadrafire.com
Pour obtenir une traduction française de ce manuel, s'il vous
plaît contacter votre revendeur ou visitez
7063-513I
WARNING
WARNING
WARNING
NOTE
www.quadrafire.com
August 13, 2018

Advertisement

Table of Contents
loading

Summary of Contents for Quadra-Fire VOYAGEUR-MBK

  • Page 1 Do not over fire - If appliance or chimney connector MODEL(S): glows, you are over firing. Over firing will void your warranty. VOYAGEUR-MBK • Comply with all minimum clearances to combustibles as specified. Failure to comply may cause house VOYAGEUR-PMH fire.
  • Page 2: Table Of Contents

    M. Altering The Fireplace ..... . .17 N. Zero-Clearance Fireplace ....17 Quadra-Fire is a registered trademark of Hearth & Home Technologies. 7063-513I...
  • Page 3: Important Safety Information

    (UM) 84-HUD and NPFA211 in the U.S.A. and the ULC S628-93 and CAN/CSA-B365 Installation Codes in Canada. The Quadra-Fire Voyageur (ACC) meets the U.S. Environmental Protection Agency’s crib wood emission limits for wood heaters sold after May 15, 2015. This wood appliance needs periodic inspection and repair for proper operation. Consult the owner’s manual for further information.
  • Page 4: Mobile Home Approved

    VOYAGEUR Insert ACC C. Mobile Home Approved WARNING • This appliance is approved for mobile home installations; when not installed in a sleeping room and Fire Risk. when an outside combustion air inlet is provided. Hearth & Home Technologies disclaims any •...
  • Page 5: Getting Started

    VOYAGEUR Insert ACC Install Guide Getting Started A. Design and Installation Considerations B. Draft Draft is the pressure difference needed to vent appliances CAUTION successfully. When a appliance is drafting successfully, all combustion byproducts are exiting the home through the Check building codes prior to installation.
  • Page 6: Negative Pressure

    VOYAGEUR Insert ACC C. Negative Pressure WARNING WARNING Fire Risk. Hearth & Home Technologies disclaims any Asphyxiation Risk. responsibility for, and the warranty will be voided • Negative pressure can cause spillage by, the following actions: of combustion fumes, soot and carbon monoxide.
  • Page 7: Install Checklist

    VOYAGEUR Insert ACC F. Install Checklist ATTENTION INSTALLER: Follow this Standard Work Checklist This standard work checklist is to be used by the installer in conjuction with, not istead of, the instructions contained in this installation manual. _________________________________________________________________________________ Customer: ______________________________________________________________________________ Date Installe: ______________________________________________________________________________ Lot / Address:...
  • Page 8: Dimensions And Clearances

    VOYAGEUR Insert ACC Dimensions and Clearances A. Appliance Dimensions NOTE: Flue Collar size is 6 inch (152mm) diameter (ID) 32-7/8 in [834mm] 33 in (837mm) 33 in (837mm) 19-5/8 in [499mm] 19-5/8 in (499mm) 19-5/8 in (499mm) 18-1/8 in 18-1/8 in 18-1/4 in 18-1/4 in [460mm]...
  • Page 9 VOYAGEUR Insert ACC 14 in 14 in 13-7/8 in (357mm) (357mm) [353mm] 22-1/8 in 22-1/8 in 22-1/8 in [562mm] 15° (562mm) (562mm) 15° 15° 21-1/2 in 21-1/2 in 21-1/2 in [546mm] (546mm) (546mm) 3-7/8 in 3-7/8 in 3 in 3 in 3-7/8in [97mm] 3 in [76mm] (97mm)
  • Page 10: Clearances To Combustibles

    VOYAGEUR Insert ACC B. Clearances to Combustibles United States and Canada (UL and ULC) TOP TRIM (3/4” max) 31-1/4 21-1/4 794mm 540mm 40-3/16 1021mm Minimum Opening Dimensions Inches Millimeters Height 22-3/8 Front Width (Steel 33-1/4 Surround) USA 18-3/4 HEARTH CANADA Front Width (Cast EXTENSION 22-3/4 (578mm)
  • Page 11: Calculating Alternate Floor Protection

    VOYAGEUR Insert ACC Zero Clearance Floor Thermal Protection USA and CANADA CANADA ONLY Hearth Height Greater Hearth Height than 7 inches 0 to 7 inches (178mm) (0 to 178mm) Thermal Thermal Protection Protection Required Required Minimum R value = 0.52 Greater than 7 inch (178mm) 0 to 7inch (0 to 178mm)
  • Page 12: Chimney Systems

    VOYAGEUR Insert ACC Chimney Systems A. Locating Your Appliance & Chimney Location of the appliance and chimney will affect performance. As shown in Figure 12.1 the chimney should: • Install through the warm space enclosed by the building envelope. This helps to produce more draft, especially during lighting and die down of the fire.
  • Page 13: Chimney Termination Requirements

    VOYAGEUR Insert ACC B. Chimney Termination Requirements NOTICE: Locating the appliance in a basement or in a location of considerable air movement can cause Follow manufacturer’s instructions for clearance, intermittent smoke spillage from appliance. Do securing flashing and terminating the chimney (Figure not locate appliance near: 13.1 &...
  • Page 14: Venting Systems

    VOYAGEUR Insert ACC D. Venting Systems WARNING Chimney Connector: It is also known as flue pipe or stove pipe. It must be Improper installation, adjustment, alteration, service or 6 inches (152mm) minimum diameter stainless steel maintenance can cause injury or property damage. Refer connector pipe.
  • Page 15: Masonry Chimney

    VOYAGEUR Insert ACC I. Masonry Chimney • An equivalent liner must be a listed chimney liner system or other approved material. This insert conforms with the UL 1482 and ULC S628 • No dilution air is allowed to enter the chimney. (Canada) in all respects, and is approved to UL &...
  • Page 16: Metal Heat Circulating Masonry

    VOYAGEUR Insert ACC J. Metal Heat Circulating Masonry • No dilution air is allowed to enter the chimney. a. Secure the fireplace damper in the open position. This insert conforms with the safety standard UL-1482 and If this cannot be accomplished, it will be necessary ULC S628 (Canada) in all respects and is approved to UL to remove the damper and ULC safety standards for installation and use within a...
  • Page 17: Ovalizing Round Stainless Steel Liners

    VOYAGEUR Insert ACC L. Ovalizing Round Stainless Steel Liners N. Zero-Clearance Fireplace Ovalizing round stainless steel liners to accommodate the A permit may be required for installations, final approval is liner passing through the damper region of a fireplace is an contingent of the authority having local jurisdiction.
  • Page 18: Appliance Set-Up

    VOYAGEUR Insert ACC Appliance Set-Up A. Outside Air Kit Installation A source of air (oxygen) is necessary in order for combustion to take place. Whatever combustion air is consumed by the fire must be replaced. Air is replaced via air leakage around windows and under doors. In homes that have tightly sealed doors and windows, an outside air source is needed.
  • Page 19: Securing Stove Pipe/Liner To Flue Collar

    Simpson Duravent Pipe Distributor or from your local sealant such as stove mastic (Figure 19.1). Quadra-Fire dealer, Part Number DV-6DLR-E15ADSS. 2. Attach gasket to bottom side of flue collar with a thin Figure 19.3 shows a vertical installation and also how to coat of silicone.
  • Page 20: Securing Appliance To Stove Pipe/Liner

    VOYAGEUR Insert ACC E. Securing Appliance to Stove Pipe/Liner F. Surround & Trim Kit Installation 1. Once you have the appliance in place and secured, STANDARD SIZE: 43 IN. W X 31 IN. H reach up through the flue opening and grab the LARGE SIZE: 51 IN.
  • Page 21: Standard Surround & Cast Trim Kit

    VOYAGEUR Insert ACC G. Standard Surround & Cast Trim Kit STANDARD SIZE: 42-1/2 IN. W X 30 IN. H 6. Secure the magnet to the bracket and attach the magnet and bracket to each metal side piece at the LARGE SIZE: 48 IN. W X 34 IN. H bottom.
  • Page 22: All Cast Surround Kit

    VOYAGEUR Insert ACC H. All Cast Surround Kit SIZE: 40 IN. W X 30 IN. H Included in Surround Kit: (2) side pieces, left and right; (1) l top piece; (1) fastener package. Tools Needed: Powered 4 to 6 inches long Phillips head screw driver;...
  • Page 23: Blower Cord Installation On Left Side

    VOYAGEUR Insert ACC I. Blower Cord Installation on Left Side Overview: You are removing the power cord from the blower controls, re-routing the cord to the left side and re- The blower cord is shipped to be installed on the right side installing the power cord to the blower controls.
  • Page 24 VOYAGEUR Insert ACC 4. Remove the 2 screws at the top of the control plate. 6. Remove the screw that is holding the ground lug to the Push the bottom of the control plate to the inside of control plate. the appliance and partially remove the control plate assembly.
  • Page 25 VOYAGEUR Insert ACC 8. The power cord is now disconnected from the blower 10. Replace the strain relief on the power cord in the same control plate. Pull the cord out through the right side of position as before. Locate the indentation on the cord the appliance.
  • Page 26 VOYAGEUR Insert ACC 12. Insert the control plate assembly back into the appliance as shown. Tilt the assembly forward and then lift up and rotate the bottom towards the front of the appliance at the same time ensure that the snap disc holder is properly seated.
  • Page 27: Mobile Home Installation

    VOYAGEUR Insert ACC Mobile Home Installation You must use a Quadra-Fire Outside Air Kit Part #: Spark Arestor Cap OAK-ACC 1. An outside air inlet must be provided for combustion Storm Collar and must remain clear of leaves, debris, ice and/or Roof Flashing snow.
  • Page 28: Reference Materials

    VOYAGEUR Insert ACC Reference Materials A. Service and Maintenance Log Date of Service Performed By Description of Service 7063-513I August 13, 2018...
  • Page 29 VOYAGEUR Insert ACC Date of Service Performed By Description of Service August 13, 2018 7063-513I...
  • Page 30: Accessory List

    VOYAGEUR Insert ACC B. Accessory List VOYAGEUR Service Parts Beginning Manufacturing Date: Sept 2010 Ending Manufacturing Date: Active #29 Trim Assembly #28 Surround Assembly 29.2 29.3 29.1 28.1 28.2 29.4 28.3 29.5 IMPORTANT: THIS IS DATED INFORMATION . Parts must be ordered from a dealer or Stocked Hearth and Home Technologies does not sell directly to consumers distributor.
  • Page 31 VOYAGEUR Insert ACC VOYAGEUR Service Parts Beginning Manufacturing Date: Sept 2010 Ending Manufacturing Date: Active IMPORTANT: THIS IS DATED INFORMATION . Parts must be ordered from a dealer or Stocked Hearth and Home Technologies does not sell directly to consumers distributor.
  • Page 32 Hearth & Home Technologies 352 Mountain House Road Halifax, PA 17032 Division of HNI INDUSTRIES Please contact your Quadra-Fire dealer with any questions or concerns. For the number of your nearest Quadra-Fire dealer log onto www.quadrafire.com CAUTION DO NOT DISCARD THIS MANUAL...

This manual is also suitable for:

Quadra-fire voyageur-pmh