Swimming Pool - Viessmann Vitocal 300-G Installation And Service Instructions Manual

Compact heat pump with electric drive type bw/bwc, ww/wwc
Table of Contents

Advertisement

Temperature differential cooling
A Set room temperature
B Cooling limit temperature
C Selected value "Temp. diff. cool-
ing"
D Adjusted outside temperature
E Cooling function ON
F Cooling function OFF

Swimming pool

Parameter
7008
Specify whether a swimming pool is
connected and heated.
Note
Initially set parameter "External
extension" (7010) to "Yes" (see
page 141). If that has not been done,
then parameter "Swimming pool" will
not be displayed.
Cascade control (lead appliance)
Parameter
700A
System definition control settings
(cont.)
Access
"Device settings"
"Programming"
"System definition"
y to "Temp. diff. cooling"
5 or %
Standard setting
Setting range
Access
"Device settings"
"Programming"
"System definition"
y to"Swimming pool"
"YES" or "NO"
Standard setting
Setting range
Set whether the heat pump operates
as lead appliance in a cascade com-
prising several heat pumps.
4,0 K
1,0 to 20,0 K
No
Yes/No
139