Technical Data - Rangemaster Professional+ User Manual

90 dual fuel fsd
Table of Contents

Advertisement

10. Technical Data

The cooker is category II2H3+
It is supplied set for group H natural gas. A conversion kit from NG to LP is packed with the cooker.
INSTALLER: Please leave these instructions with the User.
DATA BADGE LOCATION: Cooker back, serial number repeater badge below oven door opening.
Connections
Gas (Rp ½ at rear right-hand side)
Natural gas
Butane
Propane
(See the appliance badge for test pressures)
Dimensions
Overall height
Overall width
Overall depth
Refer to 'Positioning the Cooker' .
Ratings
Hotplate
Wok burner
Large burner
Medium burner
Small burner
Oven Efficiency
Ovens
Maximum output
Energy efficiency class on a scale
of A (more efficient) to G (less efficient)
Energy consumption based on standard load
Usable volume (litres)
Size
Time to cook standard load
Surface area of the grid
Grill
Maximum total electrical load at 230V 7.4kW (approximate total including oven lights, oven fan, etc.)
20mbar
29mbar
37mbar
Natural Gas 20mb
Injector
internal 80
3.5kW
external 129
3.0kW
134
1.7kW
109
1.0kW
75
2.3kW
ArtNo.105-0008 - Technical data - 90 induction - Elan
Electric
220-240V 50Hz
minimum 898mm
Screw
96
3.5kW (246g/h)
54
3.0kW (210g/h)
39
1.7kW 119g/h)
38
1.0kW (70g/h)
Main oven
Forced air convection
2.5kW
A
0.85kWh
67
Large
38 minutes
1400cm
27
maximum 925mm
900mm
650mm
L.P. Gas
Injector
internal 54
external 77
87
68
51
Tall oven
Forced air convection
2.5kW
0.95kWh
Medium
49 minutes
790cm
2
Screw
57
40
32
28
B
53
2