Vitotronic 100, GC1B Installation and Service
Category 4 "Solar"
Only in conjunction with solar control module, type SM1.
Coding
Coding in the Delivered Condition
Speed control solar circuit pump
02:0
Solar circuit pump (multi stage) without speed
control by solar control module SM1.
DHW tank Maximum Temperature
08:60
The solar circuit pump stops when the actual
DHW temperature reaches the maximum DHW
tank temperature 140ºF (60°C).
Stagnation Time Reduction
0A:5
To protect system components and heat transfer
medium:
the speed of the solar circuit pump is reduced
if the actual DHW temperature is 5 K below
the maximum DHW tank temperature
Flow Rate Solar Circuit
0F:70
The solar circuit flow rate at maximum pump
speed is 7 L/min.
Extended Solar Control Functions
20:0
No extended control functions enabled.
Possible Change
02:1
Solar circuit pump (multi stage) is speed-
controlled with wave pack control.
02:2
Solar circuit pump is speed-controlled with
PWM control.
08:10
The maximum DHW tank temperature is
to
adjustable from 50 to 194ºF (10 to 90°C).
08:90
0A:0
Stagnation time reduction is disabled.
0A:1
Value for stagnation time reduction
to
is adjustable from 1 to 40 K.
0A:40
0F:1
Flow rate adjustable from 0.1 to 25.5 L/min;
to
1 step
0.1 L/min.
0F:255
20:1
Additional function for DHW heating.
20:2
Differential temperature control 2.
20:3
Differential temperature control 2 and
auxiliary function.
20:4
Differential temperature control 2 for central
heating backup.
20:5
Thermostat function.
20:6
Thermostat function and auxiliary function.
20:7
Solar heating via external heat exchanger
without additional temperature sensor.
20:8
Solar heating via external heat exchanger
with additional temperature sensor.
20:9
Solar heating of two DHW tanks.
Coding Level 1
101