Outdoor Unit - Daikin SkyAir Super Inverter 70 D Series Service Manual

Split system air conditioners d series;
Table of Contents

Advertisement

Electric Function Parts
3.2

Outdoor Unit

MIC
Compressor
M1F
Fan motor
M2F
Pressure
S1PH
For high pressure
switch
Pressure
SENPL
For low pressure
sensor
Thermist
R1T
For outdoor air
or
Thermist
For outdoor unit
R2T
or
heat exchanger
Thermist
For discharge
R3T
or
pipe
Thermist
R4T
For suction pipe
or
Thermist
R5T
Fin thermistor
or
J1HC
Crank case heater
Y1R
4-way valve
Electronic expansion
Y1E
valve
For
receiver
Solenoid
Y1S
gas
valve
purging
(SVG)
For
supercool
Solenoid
Y2S
heat
valve
exchanger
(SVC)
A1P
Control P.C. board
A2P
Inverter P.C. board
A3P
Indication P.C. board
PM
Power module
72
Main
body
Coil
Main
body
Coil
Main
body
[3P078909-4]
Coil
TEV-MOAJ901B1
Main
body
[3P078909-5]
Coil
TEV-MOAJ902B1
[3P050185-3]
Inside [ ] shows drawing numbers.
RZP71DV1
2YC63AXD (Swing)
55W [3P079118-1]
ACB-DB143 [3P083074-1]
OFF: 2.94
ON: 2.16
±0.15(MPa)
PS8040A [3SA48112-1]
[4P082218-1]
[3SA48004-5]
[3SA48009-4]
[3SA48002-4]
Included in inverter PCB
[3P079432-1] VK24
[3P079433-2] LB81000
[3P078905-1] CAM20-B20YPDM-1
[3P078907-1] CAM-MD12DM-2
[3P078908-1] TEV1920D
[3P078908-1] TEV1920D
[2P079303-3]
[2P080066-3]
[4P079304-1]
RZP71DVAL
0
±
(MPa)
0.1
[3P078909-1]
TEV-MOAG901B1
[3P078909-2]
TEV-MOAG902B1
[3EB10021-1]
Function and Operation
SiE25-110

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Skyair super inverter 70Skyair r-407c

Table of Contents