  • Page 1 INSTALLATION MANUAL R-407C Split series outdoor units RY35EAZ7V1 RY45EAZ7V1...
  • Page 2 fi ˆ˜ ÚÔÛ‰ÈÔÚ›˙ÂÙ·È ÛÙÔ ∞Ú¯Â›Ô ∆¯ÓÈ΋˜ ∫·Ù·Û΢‹˜ DAIKIN.TCF.001 Î·È ÎÚ›ÓÂÙ·È ıÂÙÈο · fi ÙÔ KEMA Û‡Ìʈӷ Ì ÙÔ ¶ÈÛÙÔ ÔÈËÙÈÎfi 58242-KRQ/ECM95-4224. Nota tal como estabelecido no Ficheiro Técnico de Construção DAIKIN.TCF.001 e com o parecer positivo de KEMA de acordo com o Certificado 58242-KRQ/ECM95-4224. Bemærk som anført i den Tekniske Konstruktionsfil DAIKIN.TCF.001 og positivt vurderet af KEMA i henhold til Certifikat 58242-KRQ/ECM95-4224.
  • Page 3 5 ØA 6 ØB RY35EAZ7 Ø12.7mm or 1/2" CuT Ø6.4mm or 1/4" CuT RY45EAZ7 Ø15.9mm or 5/8" CuT Ø6.4mm or 1/4" CuT H 1000 ⇒ A 300 H > 1000 ⇒ A 600 RY35EAZ7 RY45EAZ7 (3TW01326-1B)
  • Page 4: Installation Manual

    Never use piping which has been used for previous installations. Only use parts which are delivered with the unit. Do never install a drier to this R-407C unit in order to guarantee its lifetime. The drying material may dissolve and damage the system.
  • Page 5 Evacuation duration: - Wire in accordance with the wiring diagrams (see figure 7) and outlook diagram Piping length (see figure 1) . The required electrical power supply is stated on the unit's Gas side piping size 15 m > 15 m nameplate.