o
S2-1
In the On (closed) position enables a
constant Clear to Send signal and enables external
clear to send.
In the Off (open) position dis-
ables the constant Clear to Send.
o
S2-2
In Off (open) position enables long line
interface.
In On (closed) position enables
RS-232-C interface.
o
S2-3, S2-4, S2-5
These switches must be set to
the correct transmitter baud rate.
Check with
PLATO Site Director to determine transmission rate
(normally set at 120 baud).
Refer to table 3-2
for correct switch settings.
o
S2-6
In the On (closed) position enables the
inserting of a parity bit on transmitted data and
parity checking on received data on the serial
channel interface.
In the Off (open) position
disables the inserting and checking of parity bits.
o
S2-7
In the Off (open) position selects the
primary (forward) channel.
In the On (closed)
position selects the low-speed (reverse) chan-
nel.
To select either the primary or low-speed
channel, switch S2-2 must be in the On position.
o
S2-8
In the On (closed) position selects
1 stop bit.
In the Off (open) position selects
2 stop bits for 6-, 7-, or 8-bit words or 1.5 stop
bits for a 5-bit word.
o
S2-9
In the On (closed) position selects
touchpanel not present.
In the Off (open) posi-
tion selects touchpanel present.
o
S2-l0
In the On (closed) position selects
16K memory.
In the Off (open) position selects
32K memory.
8) Verify that power ON/OFF switch is in OFF position.
I
Plug ac power cord into site outlet.
Replace hood
(procedure 4) and proceed with checkout procecure.
82100083 C
3-5