TABLE 2-4.
RS-232-C INTERFACE FORWARD/REVERSE
CHANNEL SELECTION
FORWARD
REVERSE
PIN
SIGNAL
SELECTED
SELECTED
RJl-2
Forward XMT
Dynamic
Mark
RJl-14
Reverse XMT
Mark
Dynamic
RJl-4
Forward RTS
ON
ON
RJl-19
Reverse RTS
ON
ON
RJl-20
DTR*
ON
ON
*Programmable, normally ON.
--
I
Once the parity generation/checking capability is enabled,
the processor can control whether this parity is even or
odd.
See section 4, subsection Programming, for a further
explanation of the function of this switch.
S2-3, S2-4, and S2-5 - Baud Rate Selection
These three switches control the PLATO transmitter baud
rate.
The settings for these switches are described in
table 2-5.
TABLE 2-5.
PLATO CHANNEL BAUD RATE SWITCH SELECTIONS
S2-3
S2-4
S2-5
FREQUENCY
ON
X*
ON
75 bps
ON
X*
OFF
120 bps
OFF
ON
X*
1200 bps
OFF
OFF
X*
External clock**
* X means that the position of that switch is
irrelevant.
** The external clock is brought in through RJl-15
(RS-232-C transmitter signal element timing) .
82100083 C