H1 Oven Control Testing Procedures - Maytag AGS1740BD series Service

Gas slide-in range
Table of Contents

Advertisement

Testing Procedures
To avoid risk of electrical shock, personal injury or death; disconnect power and gas to range before servicing,
unless testing requires power and/or gas.
H1 (AGS5830BD*, MGS5775BD*, MGS5875BD*) Oven Control Testing
Procedures
Control
Component
H1
Oven temperature
adjustment
H1
Timer
H1
Control Lock
H1
Twelve Hour off/
Sabbath mode
H1
Cook & Hold
H1
Delay Cook & Hold
H1
24-Hour Clock
H1
Factory Default
H1
Clock Display
H1
Diagnostic Code Display
H1
Temperature Display
Maytag Matrix
Models:
MGS5775BD*
MGS5875BD*
Control Panel Assembly
22
!
WARNING
Test Procedure
Press Bake pad and enter 550° F (288° C). Press
and hold Bake pad until 0° displays. Press
Autoset 0 pad to adjust oven in 5° F (-15° C)
increments, from -35° F (-37° C) to 35° F (2° C).
Press Timer pad, enter the cook time desired by
using the number pads, press Timer pad again or
wait 4 seconds.
Press Cancel and Cook & Hold pads
simultaneously for five seconds to enable. Once
enabled, press Cancel and Cook & Hold pads
simultaneously for 5 seconds to disable.
Press and hold Clock pad for 5 seconds.
Press Cook & Hold pad ( HOLD flashes), enter the
cook time using number pads, press Bake or
Convect , enter baking temperature, press Bake
or Convect again or wait 4 seconds.
Press Delay 1 pad ( DELAY flashes), enter delay
time using number pads (time to elapse before
cooking). Press Cook & Hold pad ( DELAY and
HOLD flash), enter cook time using number pads,
press Bake or Convect , enter baking temp., press
Bake or Convect again or wait 4 seconds.
Press Cancel and Favorite pads simultaneously
for 5 seconds.
Press and hold Cancel and Keep Warm pads
simultaneously for 5 seconds.
Press and hold Cancel and Clock pads
simultaneously for 5 seconds.
Press and hold Autoset 0 and power up the unit .
Press and hold Cancel and Bake pads
simultaneously for 5 seconds.
Closed circuitry resistance
(defined as continuity):
1,000 to 6,600 Ω for Cancel pad
1,000 to 10,000 Ω for all other pads
16
9
8
1
16026293
Results
While increasing or decreasing oven
temperature, this does not affect self-
cleaning temperature.
Timer can be set from 1 minute to 99
hours and 59 minutes. A beep emits
when the timer expires.
OFF appears in the display and LOCK
flashes while the oven door is locking.
The timer, clock and oven light are
operational.
Disables the normal 12-hour shutoff,
oven is operational for up to 72 .
Cook time can be between 10 minutes
and 11 hours, 59 minutes. The oven
temperature can be set from 170° F
(76.6° C) to 550° F (287.7° C)
Delay time can be between 10 minutes
and 11 hours, 59 minutes. Cook time
can be between 10 minutes and 11
hours, 59 minutes. The oven
temperature can be set from 170° F
(76.6° C) to 550° F (287.7° C)
Press Autoset 0 to select option (12-
hour time or 24-hour time).
Press Autoset to reset clock to factory
settings.
Disables clock display. Repeat
procedure to enable clock display.
Use pads 1 to 5 to cycle through codes.
Press Autoset 0 to select option
(°F or °C).
Pad
Trace
Measurement
1
13 & 15
Continuity
2
12 & 13
Continuity
3
12 & 15
Continuity
4
4 & 14
Continuity
5
4 & 12
Continuity
6
4 & 10
Continuity
7
5 & 13
Continuity
8
5 & 12
Continuity
9
5 & 10
Continuity
0
10 & 12
Continuity
Cancel
1 & 2 or
Continuity
1 & 3
Continuity
Clock
4 & 5
Continuity
Cook & Hold
7 & 4
Continuity
Bake
10 & 11
Continuity
Broil
5 & 7
Continuity
Convect
4 & 13
Continuity
Bake
7 & 14
Continuity
Convect
7 & 15
Continuity
Roast
11 & 12
Continuity
Clean
13 & 14
Continuity
Keep Warm
5 & 14
Continuity
Favorites
7 & 13
Continuity
Timer
Light
©2005 Maytag Services

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents