Control Testing Procedures - Maytag JEA8120AD Technical Information

Electric slide-in range
Table of Contents

Advertisement

Control Testing Procedures

To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless
testing requires power.
Control Component
Switch membrane assembly
JES9750BA*
Switch membrane assembly
JES9860BA*
16026928
!
WARNING
Test Procedure
Closed circuitry resistance
(defined as continuity): 2000 Max Ω
Pins 1 & 11 are shorted together for control
configuration purposes
Latch
Trace # 1
See Detail B
Closed circuitry resistance
(defined as continuity): 2000 Max Ω
Pins 1 & 10 are shorted together for control
configuration purposes
Latch
Trace # 1
See Detail B
COOLING FAN TEMPERATURES
MODE
FAN ON TEMP F (C)
Bake
300 (148.9 C)
Broil
Immediately
Clean
Immediately
Pad
1
2
3
4
5
6
7
8
9
0
Cancel
Bake
Broil
Clean
Favorites
Vent Fan
Detail B
More Options
Setup
ATM 1
ATM 2
Back
Enter
Timer 1
Timer 2
Oven Light
Pad
1
2
3
4
5
6
7
8
9
0
Cancel
Bake
Broil
Convect
Clean
Favorites
Detail B
Rapid Preheat
Vent Fan
More Options
Setup
ATM 1
ATM 2
Back
Enter
Timer 1
Timer 2
Oven Light
FAN OFF TEMP F (C)
275 (135 C)
275 (135 C)
275 (135 C)
4
Results
Trace
Measurement
2 & 7
Continuity
2 & 8
Continuity
2 & 9
Continuity
2 & 10
Continuity
2 & 11
Continuity
2 & 12
Continuity
3 & 6
Continuity
3 & 7
Continuity
3 & 8
Continuity
2 & 6
Continuity
4 & 9
Continuity
4 & 10
Continuity
4 & 11
Continuity
5 & 7
Continuity
4 & 12
Continuity
5 & 11
Continuity
5 & 8
Continuity
5 & 6
Continuity
4 & 6
Continuity
4 & 7
Continuity
3 & 9
Continuity
3 & 10
Continuity
3 & 11
Continuity
3 & 12
Continuity
4 & 8
Continuity
Trace
Measurement
2 & 7
Continuity
2 & 8
Continuity
2 & 9
Continuity
2 & 10
Continuity
2 & 11
Continuity
2 & 12
Continuity
3 & 6
Continuity
3 & 7
Continuity
3 & 8
Continuity
2 & 6
Continuity
4 & 9
Continuity
4 & 10
Continuity
4 & 11
Continuity
5 & 9
Continuity
5 & 7
Continuity
4 & 12
Continuity
5 & 10
Continuity
5 & 11
Continuity
5 & 8
Continuity
5 & 6
Continuity
4 & 6
Continuity
4 & 7
Continuity
3 & 9
Continuity
Continuity
3 & 10
3 & 11
Continuity
3 & 12
Continuity
4 & 8
Continuity
March 2006
© 2006 Maytag Services

Advertisement

Table of Contents
loading

This manual is also suitable for:

Jea7000ad

Table of Contents