Initial Setting; Switch (Address, B Rate) - SMC Networks LEC-GPR1 Series Operation Manual

Electric actuator controller gateway (gw) unit (profibus type)
Table of Contents

Advertisement

4. Initial Setting

4. 1. Switch (Address, B RATE)

The address of the gateway unit, and the transmission rate of motor controller LEC are set. Table below
shows the setting of switches.
● Node address setting
B RATE
ADDRESS
X10
0 or 8
0
0
:
9
9
1 or 9
0
0
:
2
Do not set B RATE to the value of "Unused"
Node address becomes 125 when a setup of a node address is set as a larger value than 125.
● B RATE switch
B RATE
the transmission rate of controller IF
F
:
A
9
8
7
:
2
1
0
Caution1: Set the controller IF communication speed at 115.2kbps to use the teaching box (LEC-T1-□).
Caution 2: Turn off the power supply in order to change the switch setting.
The address is shown. (0~99)
The treble is shown about the transmission rate of
controller IF
Node address
X1
0
0
1
1
:
:
8
98
9
99
0
100
1
101
:
:
5
125
Do not use
230.4kbps
Do not use
115.2kbps
- 16 -
Nod address (X100)
100 ~ 125
1 ~ 99
100 ~ 125