Errors; Introduction; Error Conditions - Lochinvar CHA 100 G CE Installation, Commissioning, User & Maintenance Instructions

Direct gas fired floor standing water heater with automatic pilot ignition
Table of Contents

Advertisement

gis
11

11.1 Introduction

11.2 Error conditions

Instruction manual CHA

Errors

This chapter covers the following errors:
Gas smell
Water leakage
Explosive ignition.
Poor flame profile.
Power Anode.
No hot water
Insufficient hot water
If the water heater goes into an "error" condition, you will be unable to draw hot
water. The frost protection will also be out of operation. These error conditions
are divided into three groups:
Lockout error from the flue gas thermostat
The safety (pushbutton) on the flue gas thermostat in the draught diverter
has been activated. After removing the cause, the pushbutton
control reset button")
must be pressed to restart the appliance.
Lockout error from the flue gas thermostat
When this happens, the red LED on the control panel will be illuminated. The
burner control is locked out.
After eliminating the cause, the appliance must be returned to service by
pressing the reset button
Blocking errors
You can recognise this condition from the fact that the appliance does not
start running even though the water temperature is lower than the setting
that you have defined using the control thermostat
thermostat").
These errors disappear automatically once the cause of the error has been
removed, after which the appliance resumes operation by itself.
The following pages provide troubleshooting tables for each type of error.
Comment
Footnotes referred to from within any table are shown at the bottom of the
last page of that table.
(7.6 "Burner control reset
button").
(7.5 "Control
(7.6 "Burner
53