USB READER CONFIGURATION

The USB interface is available for Dragon D131, OM-30x0 and C-3000 devices and
is compatible with the following Operating Systems:
Windows 98 (and later)
Mac OS 8.0 (and later)
USB Start-up
As with all USB devices, upon connection, the Host performs several checks by
communicating with the device. During this phase normal operations are suspended
(the LED on the Dragon™ D131 reader blinks). Two basic conditions must be met
before the device is ready, the correct USB driver must be loaded and sufficient
power must be supplied to the reader.
For all systems, the correct USB driver for the
default USB-KBD interface is included in the
Host Operating System and will either be loaded
automatically or will be suggested by the O.S.
and should therefore be selected from the dialog
box (the first time only).
Normally the Host supplies sufficient power to
the device and the start-up phase ends
correctly. (The reader's LED stops blinking and
the reader emits the beep OK signal).
In rare cases, if the Host does not supply
sufficient power to the device, a dialog box will
appear on the Host and the device will be
blocked (the reader's LED continues blinking). In
this case, disconnect the USB device cable at
the Host (the reader's LED stops blinking), and
then try a different USB port as indicated by the
Operating System message. (The device emits
the beep OK signal. You can now read codes).
At this point you can read the USB interface configuration code according to your
application. Load drivers from the O.S. (if requested). When configuring the USB-
COM interface, the relevant files and drivers must be installed from the USB Device
Installation
software,
http://www.datalogic.com.
The device is ready. Successive start-ups will automatically recognize the previously
loaded drivers.
which
can
be
IBM POS for Windows
4690 Operating System
First Start-Up
Connect device to
1
Load drivers
(if requested)
Select desired USB
2
interface code
(USB-KBD is default)
Load drivers
(if requested)
Read test codes.
Device is READY
downloaded
from
CONFIGURATION
Host
reader LED blinks
reader LED off - BEEP OK
the
web
page
39