Alarm Outputs; Auxiliary Power; Alarm Task Editor - Bosch NDE-8503-R User Manual

Hide thumbs Also See for NDE-8503-R:
Table of Contents

Advertisement

FLEXIDOME IP starlight 8000i
Name
Enter a name for the alarm input. This is then displayed below the icon for the alarm input on
the Live page (if configured).
Action
Select a type of action to be performed when an alarm input occurs:
Click Set to apply the changes.
4.6.6

Alarm Outputs

Configure the switching behavior of the output.
Select different events that automatically activate an output. For example, turn on a floodlight
by triggering a motion alarm and then turn the light off again when the alarm has stopped.
Idle state
Select Open for the output to operate as a normally open contact, or select Closed if the
output is to operate as a normally closed contact.
Operating mode
Select the way the output works.
For example, if you want an activated alarm to stay on after the alarm ends, select Bistable. If
you wish an activated alarm to stay on for ten seconds for example, select 10 s.
Output follows
Select the event that triggers the output.
Output name
The alarm output can be assigned a name here. This name appears on the Live page.
Toggle
Click the button to switch the alarm output manually (for example, for testing purposes or to
operate a door opener).
Click Set to apply the changes.
4.6.7

Auxiliary Power

Auxiliary Power
Check the Enable '12V OUT' output box to enable connected external devices, such as motion
detectors, with a maximum of 50 mA. The 12V OUT output can be dynamically controlled
through the Alarm Task Editor.
4.6.8

Alarm Task Editor

Editing scripts on this page overwrites all settings and entries on the other alarm pages. This
procedure cannot be reversed.
To edit this page, you should have programming knowledge and be familiar with the
information in the Alarm Task Script Language document and the English language.
As an alternative to the alarm settings on the various alarm pages, enter the desired alarm
functions in script form here. This will overwrite all settings and entries on the other alarm
pages.
1.
2.
Bosch Security Systems B.V.
None
Monochrome
This switches the camera to the monochrome mode.
Click Examples under the Alarm Task Editor field to see some script examples. A new
window opens.
Enter new scripts in the Alarm Task Editor field or change existing scripts in line with your
requirements.
User manual
Configuration | en
53
2021-01 | V02 | F.01U.385.211

Advertisement

Table of Contents
loading

Table of Contents