General Information; Specification - Secure SCT007 Installation Instructions Manual

7 day programmable room thermostat
Table of Contents

Advertisement

Before handing over a new installation to the end user,
always verify that the system responds corretly on all
programmes (see User instructions) and that the other
electrically operated equipment and controls are
correctly adjusted.
Explain how to operate the unit to the user and hand
over the User operating instruction. The SCT007 is not
user serviceable except for the replacement of batteries.
Contact type Micro dis-connection (Voltage free)
Contact rating
Power supply
Battery life
Operating voltage
Operating termperature
range
Disrt protection
Moisture protection
Storage temperature
Base material
Mounting
Dimensions
Display
Clock
Display time adjustment
Switched time adjustment 10 minutes steps
Target temperature
adjutment
Temperature control
range
Temperature differential
(Hysteresis) at 4°C
per hour
Temperature accuracy at 19.75 °C - 20.75 °C (Conventional wet
20 °C
Temperature settings
Override

GENERAL INFORMATION

SPECIFICATION

8(3) Amps 230-240 V AC
3 x AA size alkaline batteries
In excess of 2 years
3.5 - 4.75 V DC
0 °C to 40 °C double insulated
Normal situations
Normal situations
-25 °C to +60 °C
Thermoplastic, flame retardant
Directly to wall or onto a single or
double gang wiring box (to Bs4662
standard) by means of a patress
142 mm x 71 mm x 30 mm
Liquid crystal, two digit time and
temperature display and day of week
indicator
12 hour AM/PM
1 minute steps
1°C
5 °C - 30 °C
<0.5 °C
central heating system)
19.50 °C - 21.50 °C (Electric heating
up to 8 Amps)
6 per day, independent seven day
programming
Permanent temperature lock until
reset, temporary temperature override
until next preset heating period.