1. Locate the bellcrank cable assembly. It has a strap fork secured by a ball and shank on one end and
a brass threaded plug with a brass nut on the other end.
2. Refer to Figure 20 or Figure 21 depending on the handing of your installation. Spread the strap fork
over the upper bellcrank of the Rim Exit Device chassis and align the strap fork holes with the hole in
the bellcrank.
3. Secure the strap fork to the bellcrank using the #8-32 shoulder screw and #8-32 locknut. The shoulder
screw is inserted from the outside and the locknut is secured on the inside. Tighten the locknut until
it bottoms against the shoulder of the screw.
Figure 20 - Bellcrank Cable Assembly - RHR
26
Figure 21 - Bellcrank Cable Assembly - LHR