Warning: The end of the outer tube that is to be discarded must be from the
plain (unflared) end of the tube. The end of the inner tube that is to be
discarded must also be from the plain (unnotched) end of the tube.

Installation of the Lock

1. Place the inner tube into the lock case tube retainer. Make sure that the
cutout in the tube aligns with the cables and allows the tube to seat
completely in the tube retainer.
2. Feed the cables through the outer tube from the flared end. Seat the tube
into position on the tube retainer on the back of the lock case assembly. Be
careful to keep the cables pulled taut while seating the tube to avoid
pinching and damaging them.
Seat Inner Tube in Retainer
3. Refer to Figure 17. Feed the cables through the
outer, larger, tube starting from the flared end of
the tube. Seat the tube into position on the tube
retainer on the back of the lock case assembly. Be
careful to keep the cables pulled taut while seating
the tube to avoid pinching damage to them.
Alternate Method: Depending on the width of the
door, it may be easier to insert the non-flared
end of the outer tube through the spindle hole from the inside of the container and feed the cables
through the tube. Then seat the flared end of the tube on the tube retainer.
4. Place the 3.5 x 5 x 1/8 inch hardplate against the back of the CDX-09 lock case assembly.
5. Feed the cables and outer tube through the 0.5 inch hole in the door while positioning the CDX-09 and
hardplate against the door. Insert and tighten slightly two #10-32 screws nearest the strike opening (top and
bottom) to attach the CDX-09 and hardplate to the door.
Helpful Hint: If available, another inner tube inserted from the dial ring side, with the cables carefully fed
through it, can be very helpful as a guide in feeding the cables through the container wall.
6. Loosely attach the lock case assembly to the container wall with two of the four mounting screws, placing
them diagonally across from each other.
7. Verify that the lock case assembly is centered with respect to the Horizontal Reference centerline of the
lock.
8. Tighten the lock case mounting screws to hold the lock case firmly in place.
Figure 17 - Tube-Cable Assembly Relationships