Installation of Generator Cable and Cable Guides

1. Place the generator cable into the dial ring housing recess containing a post used for positioning the cable.
The hole in the cable must be positioned over the post on the dial ring, and the five gold tabs must be
exposed.
2. The Zebra connector and Zebra connector housing are assembled at the factory but may come apart during
shipment. If so, insert the Zebra connector back into the Zebra connector housing before proceeding.
CAUTION: The Zebra connector is an electrical connector. Keep it
clean!
3. Place the generator Zebra connector and connector housing assembly
over the generator cable, and press it into the recess. The hole in the
Zebra connector housing must be positioned over the post in the dial ring.
Be sure that the black Zebra connector housing is positioned.
4. Install at least one of the stick-on cable guides in an appropriate position
to restrain the cables.
5. Route the cables through the cable guide that was just installed.
6. Depending on the thick-
ness of the container,
additional cable guides
may be necessary to
ensure the cables are
sufficiently restrained. In-
stall additional guides as
needed, and route the
LCD and generator cables
through them to ensure
that the cables do not get
routed through the "KEEP
CLEAR" area, over the
Zebra connector, or near
where the geared end of
the dial hub will project
through
the
dial
cover.

Installation of the Dial Ring Cover

1. Align the dial ring cover with the dial ring so that the generator will seat into the five o'clock position and the
four aligning lugs align with the corresponding slots in the dial ring.
2. Carefully slide the dial ring cover into the dial ring.
3. Hold the dial ring cover in place and tighten the two dial ring cover mounting screws to the specified torque.

Cutting and Installing the Spindle

1. Ensure that the lock bolt is extended and remove the cam from the lock case.
2. Check the stepper motor gear positioning.