Mount Strike - Kaba Mas High Security Pedestrian Exit Device with Electric Locking Trim Installation Manual

High security pedestrian exit device with electric locking trim
Table of Contents

Advertisement

9. Attach the channel end cap using two #8-32 x 3/
8" UFPHMS with nylon patch as shown in Figure
14.

Mount Strike

1. Ensure that the Rim Exit Device centerline has been transferred to the door jamb stop.
2. Refer to Figure 15. Center strike on door jamb
stop across Rim Exit Device reference
centerline and flush to door surface.
3. Mark top and bottom screw locations, then
center punch and drill (and tap if required) for
mounting screws.
4. Apply strike to door jamb stop using two #10-24
x 3/4" FPHMS screws.
5. Check Rim Exit Device for smooth operation
and secure latchbolt engagement. Adjust strike
if required.
6. For third (center) mounting screw on strike,
mark location, center punch, drill (and tap if
required) hole. Use a #10-24 x 3/4" FPHMS
screw to mount.
14
Figure 14 - Install Channel End Cap
Figure 15 - Mount Rim Exit Device Strike