Installation Of The Lock - Kaba Mas DKX-10 Installation Manual

Hide thumbs Also See for DKX-10:
Table of Contents

Advertisement

Kaba Mas
7

Installation of the Lock

1. Place the inner tube into the lock case tube retainer. Ensure that the cutout in the tube aligns with the cables and allows
the tube to seat completely in the tube retainer.
2. Refer to Figure 5. Feed the cables through the outer, larger, tube starting from the flared end of the tube. Seat the tube
into position on the tube retainer on the back of the lock case assembly. Be careful to keep the cables pulled taut while
seating the tube to avoid pinching damage to them.
ALTERNATE METHOD: Depending on the width of the door, it may be easier to insert the non-flared end of the outer
tube through the spindle hole from the inside of the door and feed the cables through the tube, and then seat the flared
end of the tube on the tube retainer.
HELPFUL HINT: If available, another inner tube inserted from the dial ring side, with the cables carefully fed through it,
can be very helpful as a guide in feeding the cables through the door.
14
Installation Guide / DKX-10 Type II
Figure 4 - Inner and Outer Tubes
Figure 5 - Seat Inner Tube in Retainer
Document Number 548.0418 Rev. AX — 02/2019

Advertisement

Table of Contents
loading