Electrical Requirements

Electrical Requirements
For all built-in models, the electrical supply should be
located within the shaded area shown in the illustration.
Follow the National Electrical Code and local codes and
ordinances when installing the receptacle. A separate
circuit, servicing only this appliance is required.
IMPORTANT NOTE: A ground fault circuit interrupter
(GFCI) is not recommended and may cause interruption of
operation.
The outlet must be checked by a qualified electrician
to be sure that it is wired with the correct polarity.
Verify that the outlet provides 115 V AC and is
properly grounded.
Do not use an extension cord or two-prong adapter.
Electrical ground is required on this appliance. Do
not remove the power supply cord ground prong.
Location of electrical supply.
Electrical Requirements
Power Supply
Circuit Breaker
Receptacle
7"
E
(178)
6"
(152)
1
75
(1918)
FRONT VIEW
115 V AC, 60 Hz
3-prong grounding-type
12
/
"
2
15 amp