Important Note Built-In Refrigeration ......3 To ensure the safe and efficient installation of Sub-Zero equipment, please take note of the following types of Installation Preparation .
Built-In Refrigeration subzero.com Introducing New Built-In Refrigeration The importance of the installation of the Sub-Zero built-in unit cannot be overemphasized. Installation should be RATING done by a qualified installer. PLATE Before you begin the installation process, it is recom- mended that you read this entire installation guide. There are key details that you should take special care to observe during the installation.
TOOLS AND MATERIALS REQUIRED: you matches the design you are expecting to install. The • Phillips screwdriver set Sub-Zero built-in line offers the following design alterna- • Slotted screwdriver set tives: framed, overlay, flush inset and stainless steel models. The overlay model has two design applications, •...
Page 5
Sub-Zero accessory flush inset panels. Make sure that the rough opening dimensions, door swing clearance, electrical service and plumbing are correct for the model you are about to install.
Overall Dimensions All Refrigerator / All Freezer Models IMPORTANT NOTE: The heights of the all refrigerator / all freezer models have increased from 73" (1854) to 84" (2134). 84" (2134) 36" 36" 36" 24" (914) (914) (914) (610) Model BI-36R Model BI-36RG Model BI-36F ALL REFRIGERATOR...
Page 7
Overall Dimensions subzero.com Side-by-Side Models 84" (2134) 42" 42" 24" 36" (1067) (1067) (610) (914) Model BI-36S Model BI-42S Model BI-42SD SIDE VIEW WITH DISPENSER Models are shown in the stainless steel design. IMPORTANT NOTE: Throughout this guide, dimensions in parentheses are millimeters unless otherwise specified.
Opening Dimensions Standard Installation Opening Dimensions Framed, Overlay and Classic Stainless Steel Models TOP VIEW 24" (610) OPENING DEPTH OUTLINE OF UNIT WITH " (19) PANEL 24" (610) OPENING DEPTH " (2127) OPENING WIDTH OPENING HEIGHT 83" (2108) SIDE VIEW FRONT VIEW IMPORTANT NOTE: If two units are installed side by side, Opening Width...
Page 9
Opening Dimensions subzero.com Flush Inset Installation Opening Dimensions TOP VIEW " 24" (610) " 24" (610) TOP VIEW (665) DEPTH (665) OPENING FLUSH TO CLEAT FLUSH DEPTH INSET CLEAT " OUTLINE INSET TO CLEAT DEPTH (32) OF UNIT WITH CLEAT DEPTH "...
Page 10
Opening Dimensions Dual Standard Installation Opening Dimensions Framed, Overlay and Classic Stainless Steel Models TOP VIEW 24" (610) OPENING DEPTH OUTLINE OF TWO UNITS WITH " (19) PANEL 24" (610) OPENING DEPTH " (2127) OPENING WIDTH OPENING HEIGHT 83" (2108) SIDE VIEW FRONT VIEW IMPORTANT NOTE: A dual installation kit will be required for...
Page 11
Opening Dimensions subzero.com Dual Flush Inset Installation Opening Dimensions TOP VIEW " 24" (610) (665) DEPTH " 24" (610) TOP VIEW FLUSH TO CLEAT (665) OPENING INSET " FLUSH DEPTH OUTLINE OF CLEAT DEPTH (32) INSET TO CLEAT TWO UNITS WITH CLEAT "...
Electrical Requirements Electrical Requirements For all built-in models, the electrical supply should be 7" located within the shaded area shown in the illustration. (178) Follow the National Electrical Code and local codes and 6" (152) ordinances when installing the receptacle. A separate circuit, servicing only this appliance is required.
Do not use self-piercing valves. A saddle valve kit (4200880) is available from your TOP VIEW Sub-Zero dealer. The water supply line must not interfere with installation of the anti-tip brackets. FRONT VIEW IMPORTANT NOTE: A reverse osmosis system can be used provided there is constant water pressure of 30 psi (2.1 bar) to 100 psi (6.9 bar) supplied to the unit at all...
Door Clearance Door Clearance " " " (606) (606) (606) BEHIND BEHIND BEHIND FRAME FRAME FRAME " (60) " (60) " " (60) (60) All Refrigerator / All Freezer Models Over-and-Under Models Side-by-Side Models The doors of all built-in models open to a maximum of 110°. Door Clearance A 90°...
Built-In Installation subzero.com Unpack the Unit Grille Removal Uncrate the unit and inspect for any damages. Remove In order to prevent damage to the grille and to access the the wood base and discard the shipping bolts and power cord, the top grille assembly should be removed brackets that hold the wood base to the bottom of the prior to moving the unit.
Page 16
Built-In Installation Anti-Tip Bracket Installation IMPORTANT NOTE: For either wood or concrete floor applications, if the #12 x 2 " screws do not hit a wall To prevent the unit from tipping forward and provide stud or the wall plate in any of the back holes of the a stable installation, the unit must be secured in place brackets, use the provided #8–18 x 1 "...
Page 17
Built-In Installation subzero.com Anti-Tip Bracket Installation CONCRETE FLOOR APPLICATIONS INSTALL CONCRETE WEDGE ANCHORS: After properly locating the anti-tip brackets in the rough 1) Drill a " (10) diameter hole any depth exceeding the opening, drill pilot holes " (5) diameter maximum in the minimum embedment.
Page 18
Built-In Installation Position the Unit Water Line Connection Use an appliance dolly to move the unit near the rough Approximately 3' (.9 m) of " plastic tubing is connected opening. Each built-in unit is equipped with rollers, so it to the unit with a preassembled "...
Page 19
Built-In Installation subzero.com Level the Unit Once the unit is in position, extend the front leveling legs down by turning the legs clockwise to adjust the height. The rear height adjustment can be made from the front of the base. Use a "...
Page 20
Built-In Installation Door Adjustment The doors for built-in side-by-side models and the upper door on over-and-under models can be adjusted in three ways: in and out, side to side tilt, and up and down (except over-and-under models). Regardless of the adjustment being made, start by slightly loosening the two upper hinge bolts on the upper hinge plate using a "...
Page 21
Built-In Installation subzero.com Anchoring Complete the Installation After door and side panels have been installed, the unit Before installing the kickplate, be sure to reinstall the drain has been leveled and door adjustment completed, anchor pan. Once the drain pan is in place, screw the kickplate the built-in unit to the opening.
Page 22
This bypass plug (7011209) is available grille. Additional 90° door stop kits (7005865) are available from your Sub-Zero dealer. To install the bypass plug: through your Sub-Zero dealer. To obtain local dealer 1) Remove water filter cartridge by pushing the end to information, visit the showroom locator section of our disengage from the filter head.
Air Purification System Panel Installation All Sub-Zero built-in units, except model BI-36F, come Before you begin installing panels, refer to the panel spec- with an advanced air purification system. A factory ifications for framed, overlay or flush inset applications...
REVEAL REVEAL " " (6) min (6) min pages 26–27. Additional panel design information can be found in the Sub-Zero built-in design guide and on our ROUT TO " " DOOR DOOR website, subzero.com. PANEL If the thickness of the custom panel is less than a "...
Page 25
Check the location of offset when you’re using specific running along the top of the drawer, and pop out the trim routing for the grip area only. Refer to the Sub-Zero molding. Refer to the illustration below. built-in design guide for a full-scale template of the...
Page 27
Panel Installation subzero.com Framed Panel Specifications BI-36S / BI-42S / BI-48S BI-42SD / BI-48SD Model BI-36S Models BI-48S and BI-48SD REFRIGERATOR REFRIGERATOR Door Panel " " Door Panel " " (503) (1767) (724) (1767) FREEZER FREEZER Door Panel " " Door Panel "...
Page 28
PANEL PANEL match dimensions listed in the overlay panel specifica- OVERLAY PANEL tions on pages 30–31. Additional panel design information can be found in the Sub-Zero built-in design guide and on BACKER PANEL BACKER our website, subzero.com. PANEL TRIM IMPORTANT NOTE: The size of the overlay panel is critical.
Page 29
Refer to the illustrations below. Sub-Zero unit. IMPORTANT NOTE: The total panel thickness (including backer and spacer, if used) in the glasswell bezel area can range from "...
PANEL PANEL match dimensions listed in the flush inset panel specifica- FLUSH INSET PANEL tions on pages 34–35. Additional panel design information can be found in the Sub-Zero built-in design guide and on BACKER PANEL BACKER our website, subzero.com. PANEL...
Page 33
The flush inset decorative panel cannot be any larger or it may restrict the air flow to the com- pressor area and cause problems with the operation of the Sub-Zero unit.
Panel Installation Flush Inset Panels Illustrations A–F provide panel offsets and reveals for all TOP VIEW TOP VIEW built-in models in a flush inset application. Refer to the DOOR / DRAWER / GRILLE chart below for reference to the illustrations relating to your specific model.
Dual flush inset panels and dual installation kits are avail- plished using two units with opposite hinges as shown in able through your Sub-Zero dealer. Refer to page 38 for illustration A below. The dual installations shown in illus- dual flush inset panel specifications.
Page 39
Door Bottom / Drawer Top DRAWER " Drawer Bottom " " SIDE VIEW SIDE VIEW SIDE VIEW Illus. E Illus. F Do not exceed the flush inset decorative panel dimensions. Exceeding dimensions could cause damage to the panels and the Sub-Zero unit.
Routing will be necessary for the side panel to fit flush Sub-Zero dealer. Refer to instructions included with the against the side of the unit. Refer also to the routing detail side panel kit when installing these side panels.
Installation Checklist subzero.com Installation Checklist The importance of the installation of the Sub-Zero built-in INSTALLATION CHECKLIST unit cannot be overemphasized. Proper installation is the Has the packing material been removed? responsibility of the selling dealer or installer. Turn the unit on. Is it operating properly?
If you are storing or disposing of your old refrigerator center. or freezer, please do it safely. Remove the To obtain the name and number of a Sub-Zero authorized doors or tightly secure service center, check the contact & support section of our the doors closed.
Need help?
Do you have a question about the Built-In Refrigeration and is the answer not in the manual?
Questions and answers