Site Preparation

Opening Dimensions

DESIGNER SERIES UNDERCOUNTER MODELS
610 mm
OPENING
DEPTH
TOP VIEW
H
W
OPENING
OPENING WIDTH
HEIGHT
SIDE VIEW
FRONT VIEW
NOTE: 89 mm finished returns will be visible and should be finished to match cabinetry.
19 mm
19 mm
TYPICAL
TYPICAL
89 mm
89 mm
FINISHED
FINISHED
FILLER
RETURN
RETURN
W
W
FRAMELESS
FRAMED
CABINETRY
CABINETRY
OPENING DIMENSIONS
W
610 mm Model
610 mm
The depth of each model is 587 mm. Allow for panel thick-
ness when planning the finished opening depth. A mini-
mum 89 mm finished return is required on all sides of the
opening. Framed cabinets require additional finished filler
material behind the face frame for a proper installation.
Refer to the illustration.
DUAL INSTALLATION
If two units are installed side by side, a dual installation kit
may be required. Installations without a custom filler strip
require a dual installation kit. If a dual installation kit is not
specified, a 51 mm filler strip is recommended between
the units. Dual installations without a filler strip can only be
accomplished using two units with opposite hinges. Refer
to the illustrations below.
Dual installation kits are available through an authorized
Sub-Zero dealer.
DUAL OPENING WIDTH
Two 610 mm Models
Dual installation kit required.
H
WITHOUT FILLER STRIP
876 mm
Opposite hinges
Same side hinges

Electrical Requirements

Installation must comply with all applicable electrical
codes and be properly grounded (earthed).
The electrical supply must be located within the shaded
area shown in the illustration below. A separate circuit
servicing only this appliance is required.
IMPORTANT NOTE: A ground fault circuit interrupter
(GFCI) is not recommended and may cause interruption of
operation.
The electrical outlet must be positioned with the ground-
ing prong to the right of the thinner blades.
ELECTRICAL REQUIREMENTS
Electrical Supply
Service
Receptacle
W
1219 mm
OPENING
127
51
mm
mm
102
mm
FLOOR
Electrical supply location
FILLER STRIP
CAUTION
The outlet must be checked by a qualified electrician
to be sure it is wired with the correct polarity. Verify
the outlet is properly grounded (earthed).
WARNING
If the supply cord is damaged, it must be replaced by
the manufacturer, its service agent or similarly quali-
fied persons in order to avoid a hazard.
WARNING
Do not locate multiple portable socket-outlets,
220-240 V AC, 50/60 Hz
power strip, or portable power supplies at the rear of
10 amp
the appliance.
grounding-type (earthed)
WARNING
Do not use an extension cord, two-prong adapter, or
remove the power cord ground prong.
Electrical
Shock
Hazard
Plug power cord directly into a properly
grounded (earthed) outlet.
Do not defeat the grounding (earthing)
nature of the plug.
Do not use adapter or extension cord.
Failure to follow these instructions could
cause serious injury or death.
See installation instructions
subzero.com | 3