Opening Door; Room Air Fan; Shutdown Procedure - Ashley AP5660L Installation And Operating Manual

Table of Contents

Advertisement

As a general rule, on lower feed rate settings, the damper should be farther to the left closing it off. On higher feed rates, the
damper should be open more by having it set more towards the right. Through trial and error, you will fi nd the best setting. Consult
your dealer if you need help.
NOTE: On heat range "1", damper should be either completely closed or open no more than a ¼ of the way. If damper is open to
far, it can cause the fi re to go out.

OPENING DOOR

If the door is opened while the stove is in operation it must be closed within 30 seconds or the stove will shut down. If the stove
shuts down push the "On/Off" button to re-start your stove. The stove will have to fully shut down and turn off before you will be
able to restart the stove.

ROOM AIR FAN

When starting your stove the Room Air Fan will not come on until the stove's heat exchanger warms up. This usually takes about
10 minutes from start-up.
IF STOVE RUNS OUT OF PELLETS
The fi re goes out and the auger motor and blowers will run until the stove cools. This will take 30 minutes or longer depending
on the heat remaining in the appliance. After the stove components stop running all lights on the display will go out and the two
digit display will begin fl ashing "E3"
REFUELING
The hopper and stove top will be hot during operation; therefore, you should always use some type of hand protection when
refueling your stove.
Never place your hand near the auger while the stove is in operation.
We recommend that you not let the hopper drop below ¼ full.
KEEP HOPPER LID CLOSED AT ALL TIMES EXCEPT WHEN REFILLING.

SHUTDOWN PROCEDURE

Turning your stove off is a matter of pressing the "POWER" button on the display board. The green light will turn back to red
when the "POWER" button is pushed. The auger motor will stop, and the blowers will continue to operate until the internal fi rebox
temperatures have fallen to a preset level.
WARNING: Never shut down this unit by unplugging it from the power source.
1.
Your stove is equipped with a high temperature thermodisc. This unit has a manual reset thermodisc. This safety switch has
two functions.
A. To recognize an overheat situation in the stove and shut down the fuel feed or auger system.
B. In case of a malfunctioning convection blower, the high-temperature thermodisc will automatically shut down the
auger, preventing the stove from overheating.
NOTE: On some units, once tripped, like a circuit breaker, the reset button will have to be pushed before restarting your stove.
On other units the thermodisc has no reset button and will reset itself once the stove has cooled. The manufacturer recommends that
you call your dealer if this occurs as this may indicate a more serious problem. A service call may be required.
2. If the combustion blower fails, an air pressure switch will automatically shut down the auger.
NOTE: Opening the stove door for more than 30 seconds during operation will cause enough pressure change to activate the air
switch, shutting the fuel feed off. The stove will shut down and show "E2" on the two digit display. The stove has to fully shut
down before restarting.
Operation
DO NOT OVERFILL HOPPER.
10