Advertisement

Available languages

Available languages

Quick Links

Owner's Instruction and Operation Manual
Model Number:
AW40E
Report Number: F20-596
Tested Per EPA Methods ALT-125, ASTM
E2515, ASTM E3053 and CSA B415 Certified to
UL 1482-2011 (R2015) and ULC-S627-00-REV1
Mobile home approved (USA ONLY)
* All Pictures In This Manual Are For Illustrative Purposes Only. Actual Product May Vary.
Save These Instructions In A Safe Place For Future Reference.
SAFETY NOTICE: If this heater is not properly installed, a house fire may result.
For your safety, follow the installation instructions. Never use make-shift
compromises during the installation of this heater. Contact local building or
fire officials about permits, restrictions and installation requirements in your
area. NEVER OPERATE THIS PRODUCT WHILE UNATTENDED.
CAUTION! Please read this entire manual before you install or use your new room
heater. Failure to follow instructions may result in property damage, bodily injury,
or even death. Improper Installation Will Void Your Warranty!
U.S. Environmental Protection Agency
Certified to comply with 2020 particulate
emissions standards.
THIS MANUAL IS SUBJECT TO CHANGE WITHOUT NOTICE.
© 2020 United States Stove Company, 227 Industrial Park Rd., South Pittsburg, TN 37380
R
CALIFORNIA PROPOSITION 65 WARNING:
This product can expose you to chemicals including carbon
monoxide, which is known to the State of California to cause
cancer, birth defects, and/or other reproductive harm. For
more information, go to
www.P65warnings.ca.gov
853769C-1002K
Ph. 800-750-2723

Advertisement

Table of Contents
loading

Summary of Contents for Ashley AW40E

  • Page 1 Owner’s Instruction and Operation Manual Model Number: AW40E Report Number: F20-596 Tested Per EPA Methods ALT-125, ASTM E2515, ASTM E3053 and CSA B415 Certified to UL 1482-2011 (R2015) and ULC-S627-00-REV1 Mobile home approved (USA ONLY) 853769C-1002K * All Pictures In This Manual Are For Illustrative Purposes Only. Actual Product May Vary.
  • Page 2 The instructions pertaining to the installation of your wood stove comply with UL-1482 (R2015) and ULC-S627-00 (R2016) standards. This manual describes the installation and operation of the Ashley, AW40E wood heater. This heater meets the 2020 U.S. Environmental Protection Agency’s cordwood emission limits for wood heaters sold after May 15, 2020.
  • Page 3: Installation Checklist

    INSTALLATION CHECKLIST Your Wood Stove should be installed by a qualified installer only. An NFI qualified Installer can be found at www.nficertified.org/public/find-an-nfi-pro/ CUSTOMER SERVICE 1-800-750-2723 ext 5050 Text to 423-301-5624 Email to: Customerservice@usstove.com COMMISSIONING CHECKLIST This Checklist is to be completed in full by the qualified person who installs this unit. Keep this page for future reference.
  • Page 4: Unpack And Inspect

    ASSEMBLY INSTRUCTIONS FOR CUSTOMER SERVICE CALL: 800-750-2723 EXT 5050 UNPACK AND INSPECT the cabinet door open, place your hand under the cabinet frame (right-hand side of the cabinet door) Remove the packing from the appliance and and pull out on the door. Follow these instructions inspect for any damage.
  • Page 5 ASSEMBLY INSTRUCTIONS 2. Locate the two hooks inside the firebox above NOTE: During opening and closing of the feed and ash doors of this heater, it may seem that the fit the fire door opening as shown. of the door is “too tight”. As the heater is fired, the gasketing “settles”...
  • Page 6: Installation

    INSTALLATION FOR CUSTOMER SERVICE CALL: 800-750-2723 EXT 5050 POSITIONING THE STOVE SAFETY NOTICE It is very important to position the wood stove as • IF THIS STOVE IS NOT PROPERLY INSTALLED, close as possible to the chimney, and in an area that A HOUSE FIRE MAY RESULT.
  • Page 7: Clearances To Combustibles

    INSTALLATION This heater must have a non-combustible floor protector with a minimum type 1 ember protection extending beneath the heater if the floor is constructed of combustible material. If a floor pad is used, it should be UL listed or equal. The floor protector should be large enough to extend under the stove and beyond each side as indicated.
  • Page 8: Chimney Connector (Stove Pipe)

    INSTALLATION CHIMNEY CONNECTOR (STOVE PIPE) 5. There is excessive condensation on windows in the winter. Install 6. A ventilation system is installed in the house. crimped 1/4” slope per foot towards stove. Male Part Downwards Flow Direction of Flue 3 screws Gases Slide the hose clamp over the aluminium flex pipe.
  • Page 9: Factory Built Chimney

    INSTALLATION draft in your chimney depends on the length of the 3. The chimney must exceed any part of the chimney, local geography, nearby obstructions and building or other obstruction within a 10’ other factors. Too much draft may cause excessive (3.04m) distance by a height of 2’...
  • Page 10: Masonry Chimney

    INSTALLATION COMBUSTIBLE WALL CHIMNEY When a metal prefabricated chimney is used, the CONNECTOR PASS-THROUGHS manufacturer’s installation instructions must be followed. You must also purchase (from the same METHOD A - 12” (305 mm) Clearance to Combustible manufacturer) and install the ceiling support Wall Member: Using a minimum thickness 3.5”...
  • Page 11 INSTALLATION METHOD D - 2” (51 mm) Clearance to Combustible Wall Member: Start with a solid-pak listed factory built chimney section at least 12” (304 mm) long, with insulation of 1” (26 mm) or more, and an inside diameter of 8” (2” [51 mm] larger than the 6” [153 mm] chimney connector).
  • Page 12 OPERATION INSTRUCTIONS NEVER OPERATE THIS PRODUCT WHILE UNATTENDED WOOD STOVE UTILIZATION CAUTIONS: HOUSE FIRE HAZARDS Your heating appliance was designed to burn well • DO STORE WOOD FLOOR seasoned natural wood only; no other materials PROTECTOR, UNDERNEATH STOVEPIPE(S) should be burned. Any type of well seasoned OR ANYWHERE WITHIN CLEARANCES TO natural wood may be used in your stove, but COMBUSTIBLE SURFACES SPECIFIED FOR...
  • Page 13: Testing Your Wood

    OPERATION INSTRUCTIONS • Keep the air control full open and close the door. stored directly on the ground. Air should circulate If ignition of the piece is accomplished within 90 through the logs. A 24” to 48” air space should be left between each row of logs, which should be seconds from the time it was placed in the stove, your wood is correctly dried.
  • Page 14: Fueling Instructions

    OPERATION INSTRUCTIONS FUELING INSTRUCTIONS For a medium burn, once the high burn fuel load is This wood stove has been certified by the US EPA burned down to an established coal bed, load the unit with 27-28 lbs of cordwood and keep the door to meet strict 2020 guidelines.
  • Page 15: Air Tubes

    OPERATION INSTRUCTIONS Make sure the blades do not have build up. Caution! and moisture leaving your stove. Learn to adjust the air settings of your specific unit to produce the Route the Power Supply Cord away from the heat source and out of high traffic areas. smallest amount of visible smoke.
  • Page 16: Chimney Maintenance

    CHIMNEY MAINTENANCE NEVER OPERATE THIS PRODUCT WHILE UNATTENDED TO PREVENT CREOSOTE BUILD UP CAUTION: • Always burn dry wood. This allows clean burns DO NOT OVERFIRE APPLIANCE. YOU ARE and higher chimney temperatures, therefore less OVERFIRING IF ANY PART OF THE APPLIANCE creosote deposit.
  • Page 17: How To Order Repair Parts

    CHIMNEY MAINTENANCE GASKET CARE CAUTIONS: • ASHES COULD CONTAIN HOT EMBERS EVEN WARNING: AFTER TWO DAYS WITHOUT OPERATING NEVER OPERATE THE STOVE WITHOUT A THE STOVE. GASKET OR WITH A BROKEN ONE. DAMAGE • THE ASH PAN CAN BECOME VERY HOT. TO THE STOVE OR EVEN HOUSE FIRE MAY WEAR GLOVES TO PREVENT INJURY.
  • Page 18: Blower Wiring Diagram

    BLOWER WIRING DIAGRAM DANGER: SHOCK HAZARD DISCONNECT POWER SOURCE BEFORE INSTALLATION AND WHENEVER SERVICING BLOWER ASSEMBLY. CAUTION: MOVING PARTS CAN CAUSE INJURY. DO NOT OPERATE WITH COVER REMOVED. WHITE / BLACK / BLACK / BLANC NOIR NOIR BLACK / BLACK / BLACK / NOIR NOIR...
  • Page 19: Repair Parts

    REPAIR PARTS © 2020 United States Stove Company...
  • Page 20 To order parts: Call 1-800-750-2723 Ext 5051 or Email to: parts@usstove.com IN ORDER TO MAINTAIN WARRANTY, COMPONENTS MUST BE REPLACED USING ASHLEY PARTS PURCHASED THROUGH YOUR DEALER OR DIRECTLY FROM ASHLEY. USE OF THIRD PARTY COMPONENTS WILL VOID THE WARRANTY.
  • Page 21 To order parts: Call 1-800-750-2723 Ext 5051 or Email to: parts@usstove.com IN ORDER TO MAINTAIN WARRANTY, COMPONENTS MUST BE REPLACED USING ASHLEY PARTS PURCHASED THROUGH YOUR DEALER OR DIRECTLY FROM ASHLEY. USE OF THIRD PARTY COMPONENTS WILL VOID THE WARRANTY.
  • Page 22: Service Record

    SERVICE RECORD It is recommended that your heating system is serviced regularly and that the appropriate Service Interval Record is completed. SERVICE PROVIDER Before completing the appropriate Service Record below, please ensure you have carried out the service as described in the manufacturer’s instructions. Always use the manufacturer's specified spare part when replacement is necessary.
  • Page 23 ENREGISTREMENT DE SERVICE Il est recommandé que votre système de chauffage est desservi régulièrement et que le Service Interval enregistrement approprié est terminée. FOURNISSEUR DE SERVICES Avant de terminer l’enregistrement de service approprié ci-dessous, s’il vous plaît vous assurer que vous avez effectué le service tel que décrit dans le les instructions du fabricant.
  • Page 24: Pièces De Rechange

    PIÈCES DE RECHANGE Clé Qté Partie # La Description 88336 Couverture isolante Panneau déflecteur 88335 29437 Retenue de tube Côté déflecteur 29438 27291 Dessus de doublure avant 29408 Retenue à droite Brique réfractaire 893285 Support à briques supérieur 27484 Brique réfractaire ponce (4-1 / 2 X 9) 89066A 610223 Soudure du couvercle de nettoyage...
  • Page 25 PIÈCES DE RECHANGE Clé Qté Partie # La Description 67966 Armoire Haut Assy Bague Col Cheminée 22761 Boîtier Arrière 610143 6 po C.i. Col De Cheminée 40246 Joint De Collier De Cheminée 88032 Ensemble Souffleur (B36) 891492 Boîtier De Montage Du Ventilateur 25598 Rideau De Fumée 29329...
  • Page 26 PIÈCES DE RECHANGE © 2020 United States Stove Company...
  • Page 27 SCHÉMA DE CÂBLAGE DU VENTILATEUR DANGER: RISQUE D’ÉLECTROCUTION, DÉBRANCHER LA SOURCE D’ALIMENTATION AVANT L’INSTALLATION ET LORS DE L’ENTRETIEN DE L’ASSEMBLAGE DE LA SOUFFLEUSE. ATTENTION: LES PIÈCES EN MOUVEMENT PEUVENT CAUSER BLESSURE. NE PAS UTILISER AVEC LE COUVERCLE ENLEVÉ. WHITE / BLACK / BLACK / BLANC...
  • Page 28: Entretien De La Cheminée

    ENTRETIEN DE LA CHEMINÉE ENTRETIEN DES JOINT ATTENTION: • LES CENDRES POURRAIENT CONTENIR DES AVERTISSEMENT: EMBRES CHAUDES MÊME APRÈS DEUX JOURS N’UTILISEZ JAMAIS LE POÊLE SANS JOINT OU SANS FAIRE FONCTIONNER LE POÊLE. AVEC UN CASSÉ. DES DOMMAGES AU POÊLE OU À •...
  • Page 29 ENTRETIEN DE LA CHEMINÉE NE JAMAIS UTILISER CE PRODUIT SANS SURVEILLANCE POUR ÉVITER LA CONSTRUCTION DE AVERTISSEMENT: CRÉOSOTE SURCHAUFFER L’APPAREIL. VOUS • Brûlez toujours du bois sec. Cela permet des brûlures SURCHAUFFEZ SI UNE PARTIE QUELCONQUE DE propres et des températures de cheminée plus élevées, L’APPAREIL S’ALLUME EN ROUGE.
  • Page 30 INSTRUCTIONS D’UTILISATION DU BOIS paramètres d’air de votre unité spécifique pour produire aiguilles d’une montre. Il est recommandé d’éteindre la la plus petite quantité de fumée visible. Le bois qui n’a soufflerie quand l’insert n’est pas utilisé. Prudence! Route pas été correctement séché et qui a une teneur élevée en du cordon d’alimentation de la source de chaleur et hors humidité...
  • Page 31 INSTRUCTIONS D’UTILISATION DU BOIS INSTRUCTIONS DE RAVITAILLEMENT Pour une combustion moyenne, une fois que la charge de combustible à combustion élevée est brûlée dans un Ce poêle à bois a été certifié par l’US EPA pour répondre lit de charbon établi, chargez l’unité avec 27-28 lb de bois aux strictes directives 2020.
  • Page 32 INSTRUCTIONS D’UTILISATION DU BOIS dans les bûches. Un espace d’air de 24 ”à 48” doit être dans les 90 secondes à partir du moment où elle a laissé entre chaque rangée de bûches, qui doivent être été placée dans le poêle, votre bois est correctement placées à...
  • Page 33: Instructions D'utilisation

    INSTRUCTIONS D’UTILISATION NE JAMAIS UTILISER CE PRODUIT SANS SURVEILLANCE UTILISATION DU POÊLE À BOIS PRÉCAUTIONS DE SÉCURITÉ D'UTILISATION Votre appareil de chauffage a été conçu pour brûler • NE JAMAIS SURCHAUFFER CET APPAREIL EN uniquement du bois naturel bien séché; aucun autre FAISANT DES FEUX EXCESSIVEMENT CHAUDS, matériau ne doit être brûlé.
  • Page 34: Installation

    INSTALLATION en fibre de verre, à partir de la surface extérieure du métallique pour paroi unique de calibre 24 minimum. manchon mural jusqu’aux matières combustibles de Maintenez la section concentrique solid-pak avec le raccord de la cheminée et à une distance de 1 po (25,4 la paroi.
  • Page 35 INSTALLATION Le dégagement minimum de la cheminée à la brique et les matériaux combustibles est de 5 cm (2 po) (50,8 mm) Chapeau en béton Revêtement en Dégagement minimum argile réfractaire Dégagement de de 30 cm (12 po, avec vide d’air 25 mm (1 po) avec 304,8 mm) le pare-feu...
  • Page 36 INSTALLATION aux spécifications du Code national de construction. La cheminée doit avoir la hauteur requise au-dessus du Elle doit être revêtue de briques en argile réfractaires, de toit ou d’autres obstructions pour des raisons de sécurité tuiles métalliques ou en argile scellées ensemble avec un et un bon tirage.
  • Page 37 INSTALLATION FIXATION DE L’APPAREIL AU SOL espacées d’une distance égale. Le tuyau doit être court et droit. Toutes les sections installées horizontalement Utilisez les trous désignés pour fixer l’unité au sol, comme doivent être inclinées d’au moins 1/4 de pouce par pied, illustré.
  • Page 38 INSTALLATION DÉGAGEMENTS AUX COMBUSTIBLES Il est de la plus haute importance de respecter scrupuleusement les dégagements par rapport aux matériaux combustibles lors de l’installation du poêle. • La hauteur entre le plancher et le plafond doit être d’au moins 7 pi (2,13 m) dans tous les cas. •...
  • Page 39 INSTALLATION POUR L’ASSISTANCE TECHNIQUE, APPELEZ: 800-750-2723 EXT 5050 la plus vaste possible. Rappelons que la chaleur des AVIS DE SÉCURITÉ poêles à bois par rayonnement, la chaleur que nous • VOTRE POÊLE EST MAL INSTALLÉ, UN ressentons lorsque nous sommes près d’un poêle à bois. INCENDIE PEUT PROVOQUER.
  • Page 40: Instructions De Montage

    INSTRUCTIONS DE MONTAGE INSTALLATION D’UN RIDEAU DE FUMÉE Ouvrez la porte de l’armoire et la porte coupe-feu. Porte D’armoire REMARQUE: Au cours de l’ouverture et la fermeture des portes d’alimentation et de cendres de cet appareil, il peut sembler que l’ajustement de la porte est “trop serré”.
  • Page 41 INSTRUCTIONS DE MONTAGE POUR L’ASSISTANCE TECHNIQUE, APPELEZ: 800-750-2723 EXT 5050 DÉBALLER ET INSPECTER CABINET PORTE ENSEMBLE BOUTON Retirez l’emballage de l’appareil et vérifiez qu’il n’est La poignée de la porte de l’armoire est montée à l’intérieur pas endommagé. Assurez-vous que les briques sont de la porte de l’armoire pour faciliter la navigation et doit correctement positionnées...
  • Page 42: Liste De Contrôle D'installation

    LISTE DE CONTRÔLE D’INSTALLATION Votre poêle à bois ne doit être installé que par un installateur qualifié. Un installateur qualifié NFI peut être trouvé à www.nficertified.org/public/find-an-nfi-pro/ ASSISTANCE TECHNIQUE 1-800-750-2723 poste 5050 Texte au 423-301-5624 Envoyez un e-mail à: customerservice@usstove.com LISTE DE CONTRÔLE DE MISE EN SERVICE Cette liste de contrôle doit être remplie intégralement par la personne qualifiée qui installe cet appareil.
  • Page 43 Les instructions relatives à l’installation de votre poêle à bois sont conformes aux normes UL-1482 (R2015) et ULC-S627-00 (R2016). Ce manuel décrit l’installation et le fonctionnement du poêle à bois Ashley, AW40E. Cet appareil de chauffage respecte les limites d’émission de bois de construction de 2020 de la US Environmental Protection Agency pour les appareils de chauffage au bois vendus après le 15 mai 2020.
  • Page 44 Manuel D’instructions et D’utilisation Du Propriétaire Numéro De Modèle: AW40E Rapport #: F20-596 Testé selon les méthodes EPA ALT-125, ASTM E2515, ASTM E3053 et CSA B415 Certifié UL 1482-2011 (R2015) et ULC-S627-00-REV1 Mobile home approuvé (USA UNIQUEMENT) TOUS LES DROITS SONT RÉSERVÉS TOUS LES DROITS SONT RÉSERVÉS...

Table of Contents